Hoover WindTunnel MAX Instrucciones De Operación Y Servicio página 10

Ocultar thumbs Ver también para WindTunnel MAX:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FILTERS:
How to Clean
WARNING
!
To reduce the risk of personal injury, unplug
vacuum before servicing.
Do not operate cleaner without either the
secondary or final filter in place.
Secondary Filter
4.5 The secondary filter (A) protects the motor from
dirt particles.
If filter becomes dirty, pull off grill and lift out filter.
Hand wash filter in cold water. Let filter air dry for 24
hours. Reposition dry filter and grill.
What to Buy: Secondary Filter
Use only genuine HOOVER
with your vacuum. When purchasing a new
Secondary Filter, ask for HOOVER
902417001.
Final Filter
The final filter assists in the filtration process to
return clean air to the room.
4.6 To remove the filter, pull tab on filter holder down
and remove filter.
Lift out filter (B) and hand wash it in cold water.
Let filter air dry for 24 hours and reposition it on the
side of the filter holder and push filter holder back
into cleaner.
BRUSHROLL
: How to Clean
CAUTION
!
To reduce the risk of personal injury from moving
parts, unplug vacuum before servicing.
4.7 Turn vacuum over so bottom side is facing up.
Rotate red upper latch (A) counterclockwise.
4.8 Slide (2) lower latches (B) to the unlock position.
4.9 Pivot out bottom plate and remove any debris
and/or hair from brushroll.
4.10 Reposition bottom plate, aligning (2) screws
on nozzle with lower latches (4.8,B). Press firmly
on all front edges (4.10) of nozzle guard to ensure
that it is properly seated. Slide (2) lower latches to
lock in position, and rotate red upper latch clock-
wise.
Actual model may vary from images shown.
All manuals and user guides at all-guides.com
!
®
Secondary Filter
®
Part No.
!
10
4.5
A
What to Buy: Final Filter
Use only genuine HOOVER
your vacuum. When purchasing a new Final
®
Filter, ask for HOOVER
Part No. 902418001.
IMPORTANT
Allow filter to dry completely before replacing.
Dry filter on edge so air circulates on both sides
of filter. This may take up to 24 hours.
4.6
B
4.7
A
4.9
®
Final Filter with
4.8
B
4.10
Tabla de contenido

Solución de problemas

loading

Tabla de contenido