EN
Homeowner guide
Phyn is a smart water assistant that starts to learn about
your plumbing system as soon as you're connected. By
analyzing your water pressure as you go about your
routine, Phyn gets to know the subtle differences between
a running bath and a burst pipe. You will have the power
to turn off water remotely using the Phyn app.
Notes on privacy
We're open about how we use data, and we'll always get
your permission before sharing any personally identifiable
information. To learn more about our Privacy Policy, visit
your local Phyn webpage.
Notes on Wi-Fi connection & electrical supply
Phyn Plus must be connected to Wi-Fi and plugged into a
standard outlet in order for it to function properly.
Safety precautions
•
Do not block airflow to Phyn Plus. Keep immediate
surroundings clear.
•
To avoid the risk of fire and shock: use only provided
cable and power adapter.
•
We recommend using only an electrical outlet
equipped with a ground fault circuit interrupter
(GFCI).
•
Phyn does not provide third-party monitored
emergency notification or response.
Pairing Phyn Plus to Wi-Fi
1
Download the Phyn app, available in Apple
App Store and Google Play.
2
Follow the steps in the app to create your Phyn
account.
3
Follow the in-app prompts to connect Phyn Plus to
your home's Wi-Fi.
Detailed information, as well as FAQ, are available online
on your local Phyn webpage.
A guide to Phyn Plus (see Fig. 1, page 2)
A
USB-C power cable port
B
LED display panel
C
Action button (used to reset the device and engage
the shutoff valve)
D
Shutoff valve access cover
E
Power supplies
4
A guide to Phyn LED panel (see Fig. 2, page 2)
2.1
Wi-Fi pairing mode
2.2 Valve is opened, water is flowing through unit
2.3 Shutoff valve is closed, water is off
2.4 Standby mode/No power
After 120 seconds LED display goes into energy saving
mode. To wake up the device "tap" on the blue button (see
Fig. 1, E). Other LED panel states can be found online on
your local Phyn webpage.
How to control the shutoff valve
•
Via the app. Turn off your water remotely from the
Phyn app by pressing the "Water on" button on the
main menu of the app.
•
From the device, when it is powered on. Press and
hold the action button (see Fig. 1, C) until shutoff
is activated. The LED animation will change (see
Fig 2.3)
•
If device has power while blue action button is
not functioning, use manual shutoff valve. Open
the access port on the underside of the unit (see
Fig 1, G). Use a flat-bladed screwdriver to turn the
shutoff valve to the "Open"/"Close" position. To open
shutoff valve, turn the screwdriver counter-clockwise
slowly until LED panel displays valve is open (Fig
2.2) approx. 13 turns. To close shutoff valve, turn
clockwise slowly until LED panel displays valve is
closed approx. 13 turns (Fig. 2.3).
•
Emergency Situations; If you don't have power, and
you need to shut off water to your home use your
main shutoff valve.If you don't have power and need
to close the SOV, it's approx. 13 turns clockwise. To
open the shutoff valve 6-7 turns counter clockwise of
the tool should get enough water to use all fixtures
until power turns back on.
How to restore to factory settings
To restore Phyn Plus to its factory settings, tap the action
button (see Fig. 1) 3 times, then press and hold it for 5
seconds. Once the device has restored itself, you will need
to re-connect it to your home Wi-Fi network.
Power supplies requirements
Compatible with PSU plus standards, 110/220 AC 5V DC
@ 3.8A (19W).
EU Declaration of Conformity
Hereby, Phyn LLC. declares that the radio equipment is
in compliance with Directive 2014/53/EU. The full text of
the Declaration of Conformity is available at the following
internet address: http://www.phyn.com/DoC/
The operating frequency bands and the maximum
transmitted power limit are listed below:
2400 – 2484.5 MHz (20 dBm).
EU Radiation Exposure Statement
This equipment complies with EU radiation exposure limits
set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance
35cm between the radiator and your body.
User Information for Consumer Products Covered
by EU Directive 2012/19/EU on Waste Electric and
Electronic Equipment (WEEE)
European Directive 2012/19/EU requires that the
equipment bearing this symbol on the product and/
or its packaging must not be disposed of with unsorted
municipal waste. The symbol indicates that this product
should be disposed of separately from regular household
waste streams. It is your responsibility to
dispose of this and other electric and electronic
equipment via designated collection facilities
appointed by the government or local authorities.
FCC Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
This product has been tested and complies with
the specifications for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used
according to the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which is found by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment
and devices
• Connect the equipment to an outlet other than the
receiver's
• Consult a dealer or an experienced radio/TV
technician for assistance
FCC Caution: Any changes or modifications not
expressly approved by the party responsible for
compliance could void the user's authority to operate
this equipment.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure
limits set forth for an uncontrolled environment. This
equipment should be installed and operated with
minimum distance 35 cm between the radiator and
your body. This device and its antenna(s) must not be
co-located or operating in conjunction with any other
antenna or transmitter except in accordance with
FCC multi-transmitter product procedures.
Innovation, Science and Economic Development
Canada Statement
CAN ICES-3 (B)/NMB-3 (B)
Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2)
this device must accept any interference, including
interference that may cause undesired operation of
the device.
The device could automatically discontinue
transmission in case of absence of information to
transmit, or operational failure. Note that this is
not intended to prohibit transmission of control or
signaling information or the use of repetitive codes
where required by the technology.
5