H-1235
METAL DRUM PUMP
CAUTION! Pump is not to be used with acid products or flammable or explosive chemicals. Not U.L. approved.
1.
Slide pump cylinder into drum opening.
2. Loosen thumbscrew. Turn drum adapter into drum
opening. Position the pump and hand tighten the
thumbscrew.
NOTE: No tools necessary. Excessive tightening
will crush the pump barrel.
3. Install spigot into the cylinder head and tighten the
spigot collar.
NOTE: Cylinder head has a standard 1/2"
garden hose connection for easily attaching a
garden hose to the pump discharge.
PAGE 1 OF 3
1-800-295-5510
uline.com
Knob
Piston Rod
Packing Nut
Ground Stud
OPERATING
4. Screw the knob onto the piston rod.
5. Use short quick strokes to start pumping action. Then
6. After prolonged use, liquid may seep at the shaft.
7.
Pour le français, consulter la page 3.
Spigot
Spigot Collar
Thumbscrew
Drum Adapter
Pump Cylinder
IMPORTANT! Do not remove plastic sleeve on
shaft when assembling knob. It is there to limit
piston travel.
regulate stroke speed to obtain desired discharge.
Tighten the packing nut to eliminate seepage.
NOTE: Packing nut will last the life of the pump.
No need to replace in normal use.
If the pump fails to prime or deliver full volume: rinse
thoroughly with hot water or solvent to loosen caked
or solidified chemical deposits and free valve plates.
Para Español, vea página 2.
0721 IH-1235