• By the key SELECT, position yourself on the blinking LED 2 "CODE TX";
• Press key SET once to memorize the PP channel;
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed;
• The LED L2 starts to blink again to indicate that you have 10 additional sec. to store a new code;
• On expiry of those 10 sec.the LED L2 will remain steady on.
Remote control code programming of the partial / pedestrian opening (Mot. no. 1):
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET twice to memorize the PPED channel and the led will modify its blinking (110110110);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed. The extra time of 10 sec. to
store a new PPED channel is then preview as for the PP channel.
Remote control code programming of the 2nd AUX channel:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET 3 times to memorize the 2nd auxiliary channel and the led will modify its blinking (1 1 1 0 1 1 1 0);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed.
• The extra time of 10 sec. to store a new AUX channel is then preview as for the PP channel.
Important note: If a code has already been entered or all 120 codes have been memorized, by repeating the programming operation, all the
programming LEDs will start to flash, indicating that no further storing is possible.
Deletion of remote control codes:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Activate the blinking of the code to be deleted (P.P., PED. or AUX, indicated by the respective blinking);
• Press and hold down key SET for more than 5 sec.;
• The LED switches off for 2 sec. and the procedure is completed;
• If the CODE, PEDESTRIANS, or AUX codes are deleted, the LED will remain off.
Important note: If both channels codes are deleted, the LED will remain off, by the contrary if only PEDESTRIAN codes remain stored, the LED
blinking mode will change (1 1 1 1 0 1 1 1 1 0).
Rule of the first saved Remote control:
When programming remotes the following rule is applied:
if the first remote to be saved is a rolling code type, the receiver will subsequently accept only rolling code remotes (thus providing enhanced
anti-intrusion security); if the first remote to be saved is a fixed code type, the receiver will subsequently accept both fixed code remotes and
rolling code remotes, although only the fixed part of the latter will be controlled (thus effectively relinquishing the security of the rolling code
system).
8.1.3. LED L3 - CONDO: "Condominium" logic:
The enabling of the Condominium function means that during the opening movement or during the pause time the control unit will not
respond to commands sent by Pushbuttons or remotes.
In contrast, during the closing movement a command sent by the Pushbuttons or the remotes will reverse the direction of movement. This
operating mode is invaluable when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium function disabled; if the Condominium function is required, proceed
as follows:
• By the key SELECT, position yourself on the blinking LED no.3;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.4. LED L4 - MOTOR TIME: Programming of the motors stroke (max 4 min.):
It is necessary to program the working time of the motors (adjustable up to a maximum of 4 minutes).
To set a new stroke, programming must be carried out with leaves in closed position as follows:
• By the key SELECT, position yourself on the blinking LED no.4;
• Press the SET key; · Motor no.1 starts the opening phase;
• At the desired initial deceleration point, press the SET key again, LED L4 will start to flash more slowly and Motor 1 will decelerate;
• When the desired complete opening position is reached, press the SET button to end the Opening cycle;
• LED L4 will now resume flashing normally and Motor 2 will begin Opening;
• Repeat the work time programming procedure for Motor 2;
• Once
programming
of
immediately: repeat the above procedures for the Closing phase of Motor 2 and subsequently Motor 1.
the
motor
Opening
times
has
been
completed,
Motor
COMUNELLO ®Copyright 2021 - All rights reserved
2
restarts
Closing
47
Tabla de contenido
loading

Productos relacionados para Comunello Automation QUAD-24V-HP

Tabla de contenido