Whirlpool YWFE975H0HV Manual Del Usuario página 15

Ocultar thumbs Ver también para YWFE975H0HV:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make the
required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply.
4-wire (recommended)
3-wire (if 4-wire is not available)
4-Wire Connection: Direct Wire
Use this method for:
� New branch-circuit installations (1996 NEC)
� Mobile homes
� Recreational vehicles
� In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range.
Allow enough slack to easily attach wiring to the terminal
block.
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Bare (green)
ground wire
E. Line 2 (red) wire
F. Neutral (white) wire
G. Line 1 (black) wire
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the setscrew on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque as
shown in the following Bare Wire Torque Specifications chart.
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-
m)
Wire Awg
8 gauge copper
6 gauge aluminum
5. Use a hex or Phillips screwdriver to connect the bare (green)
ground wire to the range with the ground-link screw and
ground-link section. The ground wire must be attached first
and must not contact any other terminal.
6. Use 3/8" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
A. 10–32 hex nut
B. Line 2 (red)
C. Bare (green) ground
wire
D. Ground-link screw
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
D. Neutral (white) wire
E. Line 1 (black) wire
Torque
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
E. Neutral (white) wire
F. Line 1 (black)
G. Terminal lug
15
Tabla de contenido
loading

Tabla de contenido