1.5 PARAMETER CHECKING AND ADJUSTMENT 
Some parameters can be checked and adjusted by the controller. Below is the parameter list. 
Visibility 
Parameter 
U=user 
no. 
I=installer 
I/U 
13 
14 
15 
16 
17 
18 
19 
20 
21 
 
 
20
 
Description 
Tank water setting temp. (TS1) 
Water temp. difference TS6
E‐heater off tank water temp. (TS2)
E‐heater delay time 
Week disinfection temperature TS3 (related to upper 
tank temp T3) 
High temp disinfection time t2
Disinfection start up time adjusting
Pump usage selection 
Water circulation temp. setting
Offset for sanitary hot water circulation
Water difference temp. for solar pump restart
Offset for solar water circulation
Low outside temp. electrical heater activation 
Electrical heater activation during defrosting 
Disinfection period 
Lower tank temp T2 
Upper tank temp T3 
Coil temp. 
Return gas temp. 
Ambient temp. 
Hot sanitary/solar water temp. 
EXV open steps 
Range 
Default 
10 ~ 70°C 
50°C 
2 ~ 15°C
5°C 
10 ~ 85°C
60°C 
0 ~ 90
50 ~ 70°C 
70°C 
0 ~ 90min
30min 
0~23
23 
0/1/2 
15 ~ 50°C
35°C 
1 ~ 15°C
2°C 
5 ~ 20°C
5°C 
1 ~ 4°C
2°C 
0/1 
0/1 
1 ~ 30 days
7 days 
Actual testing value. Error code P1 will be shown 
0 ~ 99°C 
in case of a malfunction 
Actual testing value. Error code P2 will be shown 
0 ~ 99°C 
in case of a malfunction 
Actual testing value. Error code P3 will be shown 
‐15 ~ 99°C 
in case of a malfunction 
Actual testing value. Error code P4 will be shown 
‐15 ~ 99°C 
in case of a malfunction 
Actual testing value. Error code P5 will be shown 
‐15 ~ 99°C 
in case of a malfunction 
Actual testing value. Error code P6 will be shown 
0 ~ 125°C 
in case of a malfunction, no error if 
10 ~ 47 step
Remarks 
Adjustable (it can be also 
modified by the user in normal 
function) 
Adjustable
Adjustable
t * 5 min, Adjustable
Adjustable 
Adjustable
Adjustable
Adjustable
(0=disabled, 1=sanitary hot 
water circulation usage, 2=solar 
water circulation usage) 
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
0=off, 1=on 
Adjustable
0=off, 1=on 
Adjustable
parameter14=0 
N*10 step