Check the water discharge
1. Take off the frame the unit cover.
Take off the front frame for maintenance according to the following steps:
 Turn perpendicular airfl ow direction handle from « I » to horizontal direction.
 As shown in the picture on the right, take off two covers from the front frame and
then unfasten two fi xture screws.
 Pull the front frame towards yourself and take it off .
In case that put the front frame back, turn the perpendicular airfl ow direction handle
from « I » to horizontal, then proceed according to the third and the second steps.
You should check whether the front frame is fi rmly inside the fi xture groove on the top.
2. Check the water discharge.
 Put a cup of water into groove.
 Check whether the water fl ow through the water discharge hole.
 The outdoor unit must be fi rmly fi xed to avoid falling in the strong wind.
 Install on the cement base the drawing below.
 If it will be installed at seaside or at a place high above the ground and with strong wind, the AC should be installed against the wall to
ensure the normal operation of the fan and the blocking plate should be used.
 If it will be installed in type, the structure of the mounting surface should be made of solid stick, cement or materials with equivalent
strength, and be of enough bearing capacity. Otherwise, measures such as reinforcement, support or vibration damping should be adopt-
ed.
Installation outdoor unit bolt
Outdoor Unit Size of Shape (mm)
760X260X540
790X280X540
800X300X690(590)

INSTALLATION OF THE OUTDOOR UNIT

A(mm)
B (mm)
Left installation feat
540
280
545
315
540
326
11
Bolt
Bolt Vertical air ow
direction plate
Front frame
Pull down the front frame towards
your and take o the front frame.
Right installation feet
Air inlet
Air outlet
Outdoor Unit