Assembling The Power Plug; Filling And Venting The System - WITA go.future Z Traducción Original De La Instalación E Instrucciones De Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating instrutions
9.1

Assembling the power plug

Connect the power cable to the pump as shown. Caution: Line voltage! Observe the required
protective measures, national body regulations and local provisions at all times. The cable
cross-section may no smaller than 0.75 mm

10 Filling and Venting the System

14
WITA go.future Z
1
2
3
2
The system must be thoroughly flushed
before the pump is started up to prevent
contaminants or foreign bodies from
remaining in the system.
Fill and vent the system correctly.
Incomplete venting can lead to noises
in the pump and system.
Warning! Risk of burns!
The entire pump can be very hot, depending
on the operating state of the system.
Tighten the union nut with 30 Nm torque.
Use filter wrench.
2
Click
4
Click
. Use ferrules if using fine-wire cables.