HOW FASTEN STRAPS
THE HARNESS IS PUT ON CORRECTLY IF:
- All straps are correctly adjusted (you can thread your hand between the harness and your clothes);
- Dorsal attaching ring is correctly positioned at the level of the shoulder blades;
- Attaching/adjusting buckle is correctly positioned at the middle of the abdomen;
- The free ends of all the straps are threaded through the loops;
CONNECTING OTHER FALL ARREST DEVICES
The fall arrest device must be connected only to the
attaching elements of the harness marked by capital letter
A. So it can be connected directly to: the dorsal attaching
ring , its extension or to both the sternal attaching loops.
It is strictly forbidden to attach the fall arrest device to
only one sternal attaching loop. The dorsal attaching ring
is marked by capital letter A, marked on the crossing plate
with arrows indicating the ring. Extension of the back
hook is marked by the letter A on the label sewn inside
the end loop.
Sternal attaching loops are marked by an half of the capital letter A placed on the label sewn into each loops. See drawing.
NOTES
Before using a fall arrest system, of which the full body harness is a component, you have to check that all devices are
correctly connected. They can work without any trouble and they are certified with the obligatory standards:
- EN 353-1, EN 353-2, EN 354, EN 355, EN 360, EN 361, EN 362: for fall arrest system.
- EN 795: for anchor devices.
- EN 341: for descender devices.
USE
During use, the device should be protected from a contact with oils, acids, solvents, basics, open fire, hot metal drops and
sharp edges. You should avoid using the device in the dust laden and greasy environment.
WITHDRAWN FROM USE
The PPE must be withdrawn from use immediately when:
- any doubt arises about its good condition or its right functioning
- it has been used to arrest a fall
The PPE must be sent to the device manufacturer or to his certified representative to carry out a detailed inspection and
to value its eventual repair or destruction.
PERIODIC REVIEWS
After each 12 months of utilization the PPE must be withdrawn from use for carrying out the periodic review.
During this inspection will be established admissible time for the PPE use till next periodic review. After this period, it is
strictly forbidden to use the PPE without carrying out next periodic review. All the information concerning the periodic
review must be recorded in the Identity Card. The periodic reviews and the updating of the Identity Card can be carried out
by the manufacturer or by his authorized representative only.
ADMISSIBLE TIME OF USE
The expected average life of the PPE, if it is kept as specified in this informative note and it is subjected to all periodic
reviews, is 5 years from first use date.
THE ESSENTIAL PRINCIPLES OF USE OF PPE AGAINST FALLS FROM A HEIGHT
- PPE shall only be used by a person trained and competent in its safe use.
- PPE must not be used by a person with medical condition that could affect the safety of the equipment user in normal
and emergency use.
- A rescue plan shall be in place to deal with any emergencies that could arise during the work.
- It is forbidden to make any alterations or additions to the PPE without the manufacturer's prior written consent.
- Any repair shall only be carried out by the equipment manufacturer or his certified representative.
- PPE shall not be used outside its limitations, or for any purpose other than that for which it is intended.
- PPE should be a personal issue item.
- Before use ensure about the compatibility of items of equipment assembled into a fall arrest system.
- Periodically check connecting and adjusting of the equipment components to avoid accidental loosening or
disconnecting of the components.
- It is forbidden to use combinations of PPE in which the safe function of any items is affected by or interferes with the
safe function of another.
- Before each use of PPE it is obligatory to carry out a pre-use check of the equipment, to ensure that it is in a
cod.121034 - mod. NT06
REGULATION OF STRAPS LENGTH
REGULATION OF SHOULDER
BRACES
TO SHORTEN
TO SHORTEN
TO LENGTHEN
TO LENGTHEN
1
2
serviceable condition and operates correctly.
- During pre-use check it is necessary to inspect all elements of the equipment in respect of any damages, excessive
wear, corrosion, abrasion, cutting or incorrect acting, especially take into consideration: in full body harnesses and
belts: buckles, adjusting elements, attaching points, webbings, seams, loops; in energy absorbers: attaching loops,
webbing, seams, connectors; in textile lanyards or lifelines or guidelines: rope, loops, thimbles, connectors, adjusting
element, splices; in steel lanyards or lifelines or guidelines: cable, wires, clips, ferrules, loops, thimbles, connectors,
adjusting elements; in retractable fall arresters: cable or webbing, retractor and brake proper acting, casing, energy
absorber, connector; in guided type fall arresters: body of the fall arrester, sliding function, locking gear acting, rivets
and screws, connector, energy absorber; in connectors: main body, rivets, gate, locking gear acting
- It is essential for the safety of the user that if the product is re-sold outside the original country of destination the
reseller shall provide instructions for use, for maintenance, for periodic examination and for repair in language of the
country in which the product is to be used.
- A full body harness conformed to EN 361:2002 is the only acceptable body holding device that can be used in a fall
arrest system.
- In full body harness use only attaching points marked with big letter "A" to attach a fall arrest system. Marking
like "A/2" or a half of "A" means the necessity of attaching a fall arrest system to both attaching points together
simultaneously. It is strictly forbidden to attach a fall arrest system to the single attaching point marked "A/2" or a
half of "A".
- There are many hazards that may affect the performance of the equipment and corresponding safety precautions
that have to be observed during equipment utilization, especially: trailing or looping of lanyards or lifelines over sharp
edges; any defects like cutting, abrasion, corrosion; climatic exposure; pendulum falls; extremes of temperature;
chemical reagents; electrical conductivity.
- PPE can be cleaned without causing adverse effect on the materials in the manufacture of the
3
equipment. For textile products use mild detergents for delicate fabrics, wash by hand or in a machine and rinse in
water. Plastic parts can be cleaned only with water. When the equipment becomes wet, either from being in use or
when due cleaning, it shall be allowed to dry naturally, and shall be kept away from direct heat. In metallic products
some mechanic parts (spring, pin, hinge, etc.) can be regularly slightly lubricated to ensure better operation. Other
maintenance and cleaning procedures should be adhered to detailed instructions stated in the manual of the
equipment.
- PPE must be transported in its original package.
- PPE must be stored in their original packaging, in a well-ventilated place, protected from direct light, ultraviolet
degradation, damp environment, sharp edges, extreme temperatures and corrosive substances.
- The PPE must be disposed of in compliance with the local regulations in force on this subject (dump, incinerator).
- In the case of manufacturing defects this PPE will be replaced.
It is the responsibility of the user organisation to provide the IDENTITY CARD and to fill in the details required. The identity
card should be filled in before the first use of the equipment. Any information about the protective equipment (device name,
serial number, date of purchase, date of first use, user's name, information about reviews and repairs) shall be noted in the
IDENTITY CARD. Do not use the PPE without the identity card duly filled in.
DEVICE NAME
SERIAL NUMBER
USER'S NAME
DATE OF PURCHASE
DATE
INSPECTION REASON
1
2
3
4
5
Registered Community Trade Mark, no 016928426 c/o EUIPO - Alicante - Spain
Manufacturer: Neri S.p.A. a Socio Unico - Via 8 Marzo, 6 - 42025 Corte Tegge di Cavriago (RE) - Italia
The EU conformity declaration is available at following address: www.nerispa.com
cod.121034 - mod. NT06
IDENTITY CARD
CODE
PRODUCTION DATE
DATE OF FIRST USE
TECHNICAL INSPECTIONS
DEFECTS NOTED, REPAIRS CARRIED OUT,
PERIODIC REVIEW NEXT
OTHER RELEVANT INFORMATION
For more information, contact:
RESPONSIBLE
PERSON
DUE DATE