CIRCUIT BREAKER – The unit is equipped with a circuit breaker that will protect from
extreme overload to the motor. To reset the breaker, push in the red button on left side of
trimmer housing (in the label).
DROPPING THE UNIT – If you drop the unit, carefully inspect it for any damage before
using it again.
STORAGE
CHARGE RACK – For maximum battery performance, it is recommended that you always
keep the unit stored in its charging rack with the charger plugged in. The special 2-step
charge design of the unit's charger is designed to insure that the batteries are properly
maintained. If you choose to store the unit "off charge" during long periods of non-use (not
recommended), the unit must first be charged for 12 hours before being stored. In no cir-
cumstances should the unit be left off charge for more than three consecutive months.
TEMPERATURE – Temperature extremes limit the useful life of the battery. The best
storage place is one that is cool and dry. Store the tool away from direct sunlight, heating
pipes, furnaces, etc. Do not store where temperatures go below +40 F or above +120 F.
PREVENTING CORROSION – Fertilizers and other garden chemicals contain com-
pounds that greatly accelerate the corrosion of metals. Do not store the appliance on or adja-
cent to fertilizers or chemicals.
BATTERY RECYCLING – To preserve natural resources, please recycle or dispose of
this product's SEALED LEAD-ACID BATTERY properly. Local, state and federal laws
may prohibit disposal of sealed lead-acid batteries in ordinary trash. Consult your local
waste authority for information regarding available recycling and/or disposal options.
Figure-3
BATTERY REPLACEMENT – To replace battery, open the door on the bottom of the
trimmer by pressing the locking tab, then sliding the door backwards. Please refer to Fig-
ure-3. Once the door is removed examine the wire configuration and polarity direction prior
to disconnecting. Undo the connectors and replace the batteries.
WARNING:
When replacing the batteries, the proper polarity or direction must be ob-
served. Reverse insertion of batteries can result in leakage or explosion.
SERVICE
®
WARRANTY - Your ReadyHedger
offers a two year warranty against failure due to a
defect in material or workmanship. If you experience such a problem, American Gardener,
6