Connecting to External Devices

External devices are connected through the I/O terminal. The pinout
for the I/O terminal is shown in the following table and diagram.
Consult the software user guide for details on how to configure the
external devices.
Table:External I/O Terminals
Pin
Function
1
GND
2
RS-485 RX/TX+
3
RS-485 RX/TX-
4
I/O Common
5
Input 4(+)
6
Input 3(+)
7
Input 2(+)
8
Input 1(+)
9
Output 4
10
Output 3
11
Output 2
12
Output 1
Figure: External I/O terminal schematics and example applications.
Ground for RS-485 interface.
Half-duplex RS-485 interface for controlling
external equipment.
Shared pin for Input and Output.
The input uses a photocoupler and is electrically
isolated from the internal circuitry. The input
voltage should not exceed 12 V.
The output uses a photocoupler and is electrically
isolated from the internal circuitry. The output
terminal connections can be made with either
polarity. The output can drive a maximum load of
50 V and 120 mA.