FSLIMPRO05 - 10 - 15 - 20 - 25
1. INTRODUCTION
FSLIMPRO is especially designed and built for quick and easy installation. Installation is truly made easy
and wiring up is minimised (only the power supply cable and alarm contacts require wiring up) thanks to the
electronics incorporated in the sections and to the fact that there are no synchronism signals to be
transmitted by wire.
Sections are available in a number of lengths (from 1 to 2.5 m) so as to perfectly satisfy all protection
requirements. Fastening screws with appropriate O rings and specially shaped plugs guarantee perfect
section anchoring and seal, and durable outdoor installations.
Probe positioning to the desired height inside the FSLIMPRO so as to optimise barrier security as required is
easy and reliable thanks to the specially shaped aluminium sections and the fool-proof probe fastening
system.
2. MAIN FEATURES
• Sections in aluminium
• Top end plug in rubber and bottom end one in ABS with sponge pad protected aperture in the bottom for
air circulation against the risk of misting over because of condensate build-up inside the column and of
insects getting in and damaging the photocells.
• Cover in polycarbonate.
• Screws and O rings for secure wall anchoring.
• Equipped with four pairs of transmitter + receiver probes.
• Possibility of using up to 8 pairs of probes.
• Sliding on appropriate guide inside the Transmitter and Receiver probes and fastening by means of
screws.
• A tear-proof and anti-opening tamper on each column.
• Complete with cable routing bush hole for 6mm external diameter cable.
• Incorporated photocell amplifier with the following technical features:
multiplex and synchronised system;
management of up to 8 beams with 2 by 2 selection;
1 N.O./N.C exchange relay output.
• Easy installation and probe alignment thanks to four levels of intensity of the infra-red beams.
• Enabling of beams used by means of the four contact "BEAMS" Dip-Switch.
• Beam status indicator LED:
on = beam broken off or disabled
off = beam aligned or not broken off
• Operating mode selection via "FUNCTION" (1 and 2 ) Dip-Switch, as described in the following table:
Dip 1
OFF
ON
OFF
ON
3.
TECHNICAL SPECIFICATIONS
Power supply
Power consumption
Electric current requirement
I.R. wave length
Operating range
Relay outputs (clean exchange contact)
Relay response time
Reset time
Working temperature range
All manuals and user guides at all-guides.com
Dip 2
OFF
Beam broken off for at least 0.1seconds
At least two adjacent beams broken off for 200msec,
OFF
or two non-adjacent ones for 500msec
ON
At least two adjacent beams broken off for 200msec,
or one beam for 1second
ON
One beam broken off for 1 second
ENGLISH
Alarm activation
12Vdc
Max. 1.5 W
Max 50mA (4 pairs of enabled beams)
950 nm
10 metres indoors / 6 metres outdoors
N.O. / N.C
Minimum 100ms, maximum 1second
0.5 seconds
-20 °C to +55 °C