FSLIMPRO05 - 10 - 15 - 20 - 25
13. Check that MASTER and SLAVE red LEDS go off indicating proper beam alignment and also check for
easy beam break off.
The MASTER red LED comes on when the corresponding beam is disabled, or broken off or not properly
aligned in the MASTER to SLAVE or SLAVE to MASTER stretch.
The SLAVE red LED comes on when the corresponding beam is disabled, or broken off or not properly aligned
in the MASTER to SLAVE stretch.
14. Fit on the polycarbonate cover as shown in Figure 3.
15. Fit the plastic clip on to the plastic plug to cover up any roughly cut edges as shown in Figure 4.
16. Make a last check of the installation and a final alignment of the beams.

5.2 Settings and adjustments

1. Only enable connected beams:
identify connected beams (2,3,4) in the TX and RX probes by means of the jumper, bearing in mind that
beams come in pairs as they consist of an outgoing and an incoming probe (see par. 4).
All manuals and user guides at all-guides.com
Master Term. Strip
+12V
GND
Slave Term. Strip
+12V
Red LEDs indicating
proper beam
alignment (when off
)
ENGLISH
NC
C
NO
GND
TAMPER