GB
For units with water coil, check also the following:
• That the water coil is air free.
• That there is enough water flow.
• That incoming water is heated enough.
If the fault cannot be rectified, please contact
a qualified service technician.
Residual current circuit breaker (E)
When the installation is protected by means
of a residual current circuit breaker, which
trips when the appliance is connected,
this may be due to moisture in the heating
element. When an appliance containing a
heater element has not been used for a long
period or stored in a damp environment,
moisture can enter the element.
This should not be seen as a fault, but is
simply rectified by connecting the appliance
to the mains supply via a socket without a
safety cut-out, so that the moisture can be
eliminated from the element. The drying
time can vary from a few hours to a few days.
As a preventive measure, the unit should
occasionally be run for a short time when it is
not being used for extended periods of time.
All manuals and user guides at all-guides.com
AR3500
Safety
• For all installations of electrically heated
• Keep the areas around the air intake
• During operation the surfaces of the unit
• The unit must not be fully or partially
• This appliance is not intended for use by
products should a residual current circuit
breaker 300 mA for fire protection be used.
and exhaust grilles free from possible
obstructions!
can be hot!
covered with clothing, or similar
materials, as overheating can result in a
fire risk! (AR3500E)
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the
appliance by a person responsible for
their safety. Children should be supervised
to ensure that they do not play with the
appliance.