HEATING INSTALLATION INSTRUCTIONS
UMBRELLA MOUNTING (SOLD SEPARATELY)
1. Heater must only be mounted on metal umbrella arms.
Heater must be installed with heater surface at
least 2400mm above the floor level.
Drill mounting holes in umbrella arm.
2 x Ø6.0mm holes through both sides of arm.
1 x Ø25.0mm hole through bottom of arm only.
Ø25.0mm hole must be positioned at the end of
umbrella arm leading to power supply.
Minimum size of pole must be Ø30mm
Mounting pole material must be rated minimum 200°C.
Minimum distance from edge of the heater to any
adjacent surfaces must be 250mm.
Minimum distance from front surface of heater to
surface behind heater must be 180mm.
Any surface/material behind the heater, less than 180mm
from the front surface of the heater, must be rated
minimum 140°C. Surface/material must be positioned to
ensure no contact with mounting pole or surfaces of the
heater.
2. Attach bracket to umbrella arm with M5 bolts, washers
and nyloc nuts.
Supplied bolt suits umbrella arm up to Ø30.0mm.
3. Assemble heater bracket to heater with M5 screws.
4. Bring heater up to umbrella arm & feed power cable
into power cable hole.
5. Position heater against umbrella arm with heater
bracket channel on the inside of umbrella bracket
channel. Lock into place with self tapping screws 4
places.
6. Make electrical connection from heater to umbrella.
power supply.
All manuals and user guides at all-guides.com
117
4
www.bromicheating.com
CONTINUED...
500
960
1
Mounting Holes
2
6
Heater position relative
to mounting holes
230
3
5
11
Tabla de contenido
loading

Productos relacionados para BROMIC PLATINUM SMART-HEAT

Este manual también es adecuado para:

Bh0320001

Tabla de contenido