XPR Access INOX99 Manual Del Usuario página 5

PROGRAMMING FLOWCHART
Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Keypad
Proximity
Reader
Reader
Enter new code
(1 to 8 digits)
Present Card/Tag
before the Reader*
Notes
Memory Position for User Code is always 2 digits
* no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay in Latch Mode assuming Master Code = 000
Press 000B + 0 + 05 + 12345 + A + 3 + 05 + 1 + A + 1 + 00 + A + B.
Ex. 2: To assign User Code "6789" at Memory Position "6" and Transistor that activates for 5 seconds assuming Master Code = 000
Press 000B + 0 + 06 + 6789 + A + 3 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
above
All manuals and user guides at all-guides.com
Enter "Master Code" OR "000" (if first time use)
Validate by pressing (B)
Validation OK?
YES
1 small beep + 1 long beep + Yellow LED is 'ON'
Change
Assign Output
Master code
Press (3)
Press (0)
+
+
Memory position from
Memory
(01 to 99)
position (00)
+
Press (1) for Relay
OR
Press (2) for Transistor
OR
Press (12) for both
Press A to validate
Validation
programming
Press B (Yellow LED is 'OFF')
See: Assign Output
above
Start
Multiple small beeps
NO
+
Yellow LED blinks rapidly
Set Output Timer
Pulsed Mode (01 to 99 sec):
Relay (2A):
Press (1) + (from 01 to 99)
Transistor:
Press (2) + (from 01 to 99)
OR
Latch Mode (ON/OFF):
Press (1) or (2) + (00)
NO
OK?
YES
NO
Quit
YES
End
See: Set Output Timer
above
Delete Single
Delete All Codes
Code
Press (8)
Press (9)
+
+
(99)
Memory position from
(01 to 99)
5