11 19-inch module for SysLink system connector

11.1 Structure and function

The 19-inch module for SysLink extends the functional scope of your EduTrainer
You can connect 8 digital 24 V I/Os each with your model (e.g. MPS) using appropriate cables via two
Centronics plugs A and B. A jumper plug enables outputs to be switched off in the event of an EMERGENCY-
STOP.
The plugs A and B are set as follows in the factory:
A: Station (24 V via EMERGENCY-STOP jumper)
B: Operation (24 V continuous)
This setting can be changed via the jumpers JP1 and JP2.
The socket C enables the connection of 4 analogue inputs and 2 analogue outputs.

11.2 Commissioning

1. Connect the digital inputs/outputs to the PLC using a flat cable:
SV3/SV4 and SV7/SV8: Siemens S7 (16-pin)
SV1/SV2 and SV5/SV6: Other controller types (10-pin)
2. If using modules in parallel, these can be connected via the free insulation-displacement connectors
SV1 to SV8 using flat cables.
3. Connect the analogue inputs/outputs to the PLC using a flat cable:
SV12/SV13: Siemens S7 analogue additional module with 20-pin plug (2 x 16-pin)
SV10/SV11: Siemens S7 integrated analogue module with 40-pin plug (2 x 16-pin)
SV14: Other controller types (16-pin)
4. If using modules in parallel, these can be connected via the free insulation-displacement connector
SV14 using flat cables.
5. Connect the 24 V power supply by means of the 3-pin insulation-displacement connector SL1 or SL2.
6. Use the jumpers JP1, JP2, JP5, JP6 and JP7 to define whether the PLC modules are supplied directly via
24 V or via 24 V NA. 24 V NA is switched off in the event of an EMERGENCY-STOP.
(jumper between pins 1 and 2: supply via 24 V NA;
jumper between pins 2 and 3: supply via 24 V).
7. An EMERGENCY-STOP can be realised via the short circuit connector (24 V NA is disconnected).
8. Screw the 19-inch module into the frame.
Note
For all preferred versions EMERGENCY-STOP and bit 1.5 are connected via wire links:
10-pin plug SV6, pin 1
16-pin plug SV8, pin 9
These wire links are required if an MPS station is linked to this module. They must be removed for other
applications of this module.
70
All manuals and user guides at all-guides.com
10-pin plug SV1, pin 7
16-pin plug SV3, pin 6
®
PLC system.
© Festo Didactic GmbH & Co. KG 739319