Resin Change - unGer HydroPower Ultra UHP01 Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operation & Resin Change
4.3 Operation
1. Periodically inspect the HydroPower Ultra system during use. Ensure hoses are properly
attached. Inspect system for leaks and proper fit of top cap assembly.
2. Take care when working to ensure there is enough slack in waterfed pole tubing. This
tubing is connected to the top cover of the unit, and excessive tugging may cause the
system to tip over.
3. Tap water flows into the system's lower connection port via tap pressure and flows
upwards through the HydroPower Ultra unit. Pure water exits through the top connection.
When plumbing line pressures fall below 44 psi (3 Bar), a reduction in flow rates will be
noticeable.

5. Resin Change

5.1 Resin Change - Ultra Resin Pack
Unger's pre-measured replacement Ultra Resin Packs are designed
to allow a controlled resin expansion within a designed safety limit.
1. SHUT OFF FEED WATER SUPPLY
• Depress yellow lever on system head assembly.
• Turn tap water valve to "OFF" position.
• Disconnect waterfed wash pole hose.
2. RELEASE SYSTEM HEAD ASSEMBLY
• While continuing to depress the yellow lever, use a counter-clockwise
quarter‐turn to release system head assembly; remove and set aside.
• Reach into housing and remove exhausted resin by hand; discard
according to local regulations.
• Press yellow FastLock opening lever (fig. E) to remove pressure from
the tank.
• Steady (or "Stabilize") the base unit with your feet, gently press the top
cap down and use a counter-clockwise 1/8 turn to release top cap
assembly; remove and set aside (fig. F).
• Open all valves to facilitate the removal of the Ultra Resin Packs.
• Reach into housing and remove exhausted Ultra Resin Pack(s) by hand
with the rubber handle (fig. G); discard according to local regulations.
www.ungerglobal.com
E
F
G
9