nedis DTCTCO40WT Manual Del Usuario página 11

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
In areas without a source of combustion
In sleeping areas:
• On breathing level.
• Not in turbulent air (near windows, ceiling fans or air
conditioners).
• Not behind objects (curtains or closets).
Other areas:
• On breathing level. Depending on the activities in
the room the product should be installed on sitting
or standing height.
• Not in turbulent air (near windows, ceiling fans or air
conditioners).
• Not behind objects (curtains or closets).
Do not install the product:
• in dirty, greasy or dusty areas.
• in temperatures below -10 ºC.
• in temperatures above +40 ºC.
• in turbulent air (near ceiling fans, air conditioners or
open windows).
• within 3 meters of a high humidity source.
• within 1.5 meters of kitchen appliances.
• within 1.5 meters of a furnace or fuel burning heat
sources. The optimal distance is 6 meters.
• behind objects like curtains or closets.
• in direct sunlight.
Always remove the product from the area when the
following maintenance is performed to prevent damage
to the product:
• scouring or stripping wooden floors.
• painting.
• wallpapering.
• using adhesives or aerosols.
The following substances and gasses can cause false
alarms or permanently damage the detector: methane,
propane, iso-butane, ethylene, ethanol, alcohol, iso-
propanol, benzene, toluene, ethylacetate, acid, ether,
hydrogen, hydrogen sulphate, hepatic gas, sulphur
dioxide, aerosol, propellant, alcohol preparation,
paint, thinner, dissolvent, bonding agents, shampoo,
aftershave balm, perfume and certain cleaning agents.
Response time of the product
Concentration of CO
in air. (ppm = parts per
million)
30ppm
50ppm
100ppm
300ppm
When the alarm goes off
When the alarm beeps quickly and the red LED blinks
continuously:
• Immediately go outside.
• Call the local emergency services (Fire department).
• Do not go back into the building until the
emergency services tell you it is safe.
-
Never ignore an alarm.
Do not press the Hush/test button in case of an
4
alarm.
Assist children and/or people with mobility
4
limitations in event of an emergency.
The product cannot protect people with special
4
medical conditions.
Always check your home and appliances for
4
potential problems after an alarm.
Consult a qualified appliance technician to check
4
your appliances if the alarm reactivates within 24
hours.
11
Response time of the
product
120 minutes
60 - 90 minutes
10 - 40 minutes
3 minutes
Tabla de contenido
loading

Tabla de contenido