Advanced Setting - HTW KAIROS Manual De Usuario

Cronotermostato digital para calderas
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

- button: for Temp. & Parameters setting decrease
PRG button: Mode select & programmable setting
Operating Instructions:
5. Clock & Temperature Setting
Press and hold SET button for 5s, set the clock (Min-Hour-Weekday) by pressing + and - button, each press of
SET button will go to next item setting.
Menu
Description
01
Clock setting- Minute
02
Clock setting- Hour
03
Weekday setting

6,Advanced setting

1) Temperature calibration
Turn off the sender, long press "SET" button until the screen is lit , press "+" or "-" button to set calibration
temperature. Range: -8 °C~8°C
Press "PRG" button to enter to next step.
2) Switch differential setting
Press "+" or "-" button to change switch differential setting. Range: 0.5~5 °C
Press "PRG" button to enter to next step.
3) Floor limiting temperature (For electric heating version only)
Press "+" or "-" button to change the floor limiting temperature. Range: 25~60 °C
Press "PRG" button to enter to next step.
4) Programming mode selection
Press "+" or "-" button to '00' for 5+1+1 programming or '01' 7 individual days programming.
Press "PRG" button to enter to next step.
5) Anti-frozen function
Press "+" or "-" button to turn on/off this function or change setting temperature. Range: 3~10 °C
Press "PRG" button to enter to next step.
6) Open window detect function (OWD function)
Press "+" or "-" button to '00' for close this function and '01' for open this function.
Press "PRG" button to enter to next step.
7) OWD Detect Time
Press "+" or "-" button to change OWD Detect Time. Range:2-30 min
Press "PRG" button to enter to next step.
8) OWD Drop temp. select(within detect time)
Press "+" or "-" button to change OWD Drop temp. select . Range:2-4 ℃
Press "PRG" button to enter to next step.
9) OWD Delay time select (Return to previous working status)
Press "+" or "-" button to change OWD Delay time select. Range:10-60 min
Press "PRG" button to enter to next step.
10) Pair for sender to receiver (For RF wireless version only)
Please refer to the part 14 .
Press "PRG" button to enter to next step.
11) Reset to factory setting
Press "+" or "-" button to '01', and then press "SET" button for 5s, wait until thermostat restart
9