Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water,
swivel to the right = cold water.
14450000: The flow is changed from bath to shower
function by pulling the knop at the upper side of the
spout. After shutting off the water flow, the mixer
returns automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65° C
Centre distance:
Connections G ½":
Rate of flow 0,3 MPaes:
anti-pollution function
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work - Flow limiter in handshower isn't
6
English
max. 1 MPa
1,6 MPa
max. 80° C
150 ± 16 mm
cold right -
hot left
approx. 22 l/min
Cause
- Shower filter seal dirty
- Filters dirty
- Non return ralve didn't move
back
- Cartridge defective
- Cartridge defectiveSedimentati-
on
- Hot water limiter incor-rectly set - Set hot water limiter
removed
- Filter are dirty
- Non return ralve didn't move
back
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
0,15 MPa.
Attention!
The non return valves must be checked once a
year.
Spare parts (see page 3)
1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
escutcheon
6
S - unions
7
aerator cpl.
8
selector
9
diverter knob
10
non return valve
Remedy
- Clean filter seal between sho-
wer and hose
- Clean the filter/exchange filter
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves
14894000
96338000
94192000
94194000
92730000
94135000
94140000
13956000
94077000
94078000
94074000