Assembly instructions
OTS 735 BG | OTS 736 BG
Door closer with slide rail
OTS 735 BG / OTS 736 BG
4
All manuals and user guides at all-guides.com
Table of contents
1. Technical data ............................................................................. Page
2. Declarations of performance (DoP) ........................................... Page
3. Components and accessories ..................................................... Page 10
4. Installing and adjusting .............................................................. Page 12
4.1
Standard installation on hinge side, DIN left ............................................................Page
4.2
Standard installation on hinge side, DIN right .........................................................Page
4.3
Transom installation on side opposite to hinges, DIN left .....................................Page
4.4
Transom installation on side opposite to hinges, DIN right ...................................Page
1.
Technical data
Technical data
Door closer
Dimensions (with cover) L x H x D in mm
Closing force sizes according to EN 1154
Application range
Door leaf width, 1-leaf (min. – max.)
Door leaf width, 2-leaf (min. – max.)
DIN left/right
Transom installation on hinge side
Standard installation on side opposite to hinges (BG)
Approval for fi re and smoke protection doors
Suitable for barrier-free construction
Adjustment functions
Closing speed
Latching speed
Backcheck (ÖD/BC)
Installation/functions
Steplessly adjustable closing force
Maximum door opening angle (BS/BG)
Maximum door opening and closing angle
Opening restriction ÖB
1) 3)
Hold-open options
mechanical hold-open device FM
4)
with integrated opening restrictor,
opening beyond hold-open angle possible, adjustable hold-open angle
electromechanical hold-open device (FE),
opening beyond hold-open angle possible, adjustable hold-open angle
1) no substitute for door stop,
2) Depends on installation situation, BS = hinge side / BG = side opposite to hinges,
3) Not in conjunction with electromechanical hold-open device FE,
DE
EN
FR
ES
OTS 735 BG
268 x 63 x 44
2-5
600 mm – 1250 mm
1475 mm – 2500 mm
DIN
18040
SPEC 1104
2)
180° / 120°
180°
optional
optional
stepless 80°-140°
optional
stepless 85°-140°
4) Not suitable for fi re and smoke protection doors
4
5
12
14
16
18
OTS 736 BG
268 x 63 x 44
3-6
600 mm – 1400 mm
1475 mm – 2800 mm
DIN
18040
SPEC 1104
180° / 120°
180°
optional
optional
stepless 80°-140°
optional
stepless 85°-140°
06.2016 | G32381 | Designed in Germany