Technical Data - G-U ELTRAL S 24 L Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

General installation instructions:
 The ELTRAL S 24 L electric drive is designed exclusively for opening
and closing top hung windows, Tilt-Only windows, side hung windows,
vertical-pivot windows and horizontal-pivot windows in conjunction with
opening stays.
 Installation drawings that explain how the hardware and electric drive is
installed are available for the hardware used by Gretsch-Unitas.
Please refer to these drawings when installing our electric drives.
 Use of the electric drive for other purposes must be approved by
Gretsch-Unitas GmbH Baubeschläge. Make sure that the hinges and
hardware used permit the opening travel of the electric drive as
otherwise they could be damaged by pull or push forces.
Technical specialist personnel:
 The installation and electrical connection must be performed by
specialist personnel. Owing to their technical qualifications, these
persons have specialised knowledge in the areas of window drives,
technical standards and accident prevention regulations.
Prerequisites for installation:
 The output of the electric drive must be sufficient to open and close
the window. The limit values specified in the technical data for the
product must not be exceeded.
 The existing electrical systems must comply with the applicable
standards.
 The information regarding the permissible sash weight and sash size
for the hardware being used must be observed.
Installation:
The electric drive is delivered in the retracted condition.
1. Pull the side cover up and off. Only unscrew the countersunk head
screw in the cover on the connection side far enough to allow the
cover to be pulled up and off (see sketch).
The test run can be carried out using portable test set 230 V, 24 V
no. K-17736.
2. Fasten electric drive as specified in the required installation drawing.
3. When connecting the feed line, observe the wiring diagram overleaf.
Insert the connector into the electric drive and lay the cable round the
cord grip.
4. If the feed line is face-fixed, the side cover must be cut out.
5. Attach the side cover; screw the countersunk screw into the cover.
Load cut-off:
The electric drive switches off automatically if the load is greater than
1200 N.
Increase travel to 70 mm:
The travel is limited at the factory to 50 mm.
When used with the VENTUS F 300 fanlight opener, the travel can be
increased to 70 mm by removing the lift stop on the underside of the
electric drive.
Safety:
 Use scaffolding if the electric drives have to be installed at a height of
more than 2.5 m.
 Risk of injury or danger to life due to current.
The electric drive must be isolated from the power supply before
carrying out any connection work.
 There is a danger of crushing and shearing when installing the
window at a height below 2.5 m
Never put your hands, other parts of your body or objects
between the window sash and frame when the electric drive is in
operation.
The danger zone must be fully visible from the place of operation.
National directives, e.g. guideline for power-operated windows, doors
and gates (ZH 1/494), must be observed.
Maintenance:
 Check the electrical system, the electric drive and hardware once a
year to make sure they are working properly and are undamaged.
 Apply grease to the hardware at the designated points using acid-free
grease.
 Do not try to repair a defective electric drive by yourself.
Do not open the housing or remove parts.
In case of signs of damage to the appliance contact the manufacturer.

Technical data

Operating voltage:
Pull / Push force:
Current consumption: max. 0,7 A
Travel:
Travel speed:
Type of protection:
Follow-on distance:
Inherent noise:
Feed line:
24 V DC
max. 1200 N
max. 70 mm
approx. 0,9 mm/s
IP54
< 0,3 mm
approx. 57 dB(A)
connector plug for
2-core supply line
Tabla de contenido
loading

Tabla de contenido