Pre Alarm indication
This wireless sounder incorporates a pre - alarm feature that enhances the
security of the system, by producing a local alarm in case of sabotage.
If defined, the system sends a pre-alarm signal to the sounder at the
beginning of the entry delay. If the sounder does not receive a cancellation
signal from the system at the end of the entry time, the sounder goes into
alarm mode.
NOTE:
WisDom (Ver 4.25): Engineer menu Quick key 1) System >
2)Controls > 44) Pre alarm
Agility: Engineer menu [1][2] > Advanced > Sounder Pre alarm
LightSYS (V2.40 and above): Engineer menu 1) System > 2)
Controls > 7) Device > 5) Sounder Pre alarm
Step 3: Testing the Sounder
Communication Test
The sounder communication test performs a communication test between the
sounder receiver and the system.
To perform communication test
Access to communication test option
NOTE:
WisDom: Engineer menu > 9) Devices > 2) Sounders > 3)
Communication test
Agility: Engineer menu > 2) Testing > 5) Sounder > 1)
Communication test
LightSYS
Maintenance > Wireless Test >Wireless Sounders > Comm. Test
The value displayed indicates the last signal received from the siren (In the
WisDom it indicates the signal received during the test). A number between
00-99 indicates the strength of the communication signal between the system
and the sounder.
NOTE:
For successful communication, the strength of the signal should be
higher that the sounder receiver noise threshold level.
WisDom: Engineer menu quick key [9][2][4], Agility: Engineer menu >
2)Testing >1)Main unit > 1)Calibration).
Agility: Engineer menu: 2) Testing > 1) Main unit > 1) Calibration
LightSYS (V2.40 and above): Engineer menu: 7) Install > 2) WL
Device > 1) RX Calibration
Diagnostics
The Diagnostics menu enables to test parameters reflecting the operation of
the sounder: