All manuals and user guides at all-guides.com
TROUBLESHOOTING HINTS
Nothing operates.
Check the output power supply voltage between ' ' and '+' is of 17Vd.c. Otherwise,
disconnect the power supply from the installation and measure again. If its correct
now, it means there is a short circuit in the installation. Disconnect the power supply
from the mains and check the installation.
Check the polarity wiring.
On installations with only one monitor, check the monitor is configurated as master,
(see page 41).
On installations with two monitors, check the monitor connected to door panel(s) has
been configurated as master and slave the other monitor, (see page. 41).
Monitor don't receive calls.
Check the output power supply voltage between ' ' and '+' is of 17Vd.c. Otherwise,
disconnect the power supply from the installation and measure again. If its correct
now, it means there is a short circuit in the installation. Disconnect the power supply
from the mains and check the installation.
Check the polarity wiring.
On installations with only one monitor, check the monitor is configurated as master,
(see page 41).
On installations with two monitors, check the monitor connected to door panel(s) has
been configurated as master and slave the other monitor, (see page. 41).
Inappropiate ring tone volume.
Adjust the monitor call volume, (see page. 41).
Inappropiate audio level.
Adjust the audio levels as shown on page 37.
Does not work the intercom.
Remember that this function is only possible on installations with two monitors.
Check the intercom function steps have been realized correctly, (see page 44).
Check wiring between monitors is correct, (see page 45).
Door open function no operates.
Remember that this function is only available during call, communication and
autoswitch-on progresses.
www.golmar.es
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
–
–
47