compressor is used.
1. Pull ring on safety valve and allow it to snap
back to normal position.
▲WARNING!
replaced if it cannot be actuated or it leaks air
after ring is released.
2. Turn compressor off and release pressure
from system. Drain moisture from tank by
opening drain cock underneath tank.
3. Clean dust and dirt from motor, tank, and
airlines and pump cooling fins while
compressor is still OFF.
IMPORTANT: Locate unit as far from spraying
area, as hose will allow preventing overspray
from clogging filter.
LUBRICATION
This is an oil less type compressor requiring no
lubrication.
THERMAL OVERLOAD PROTECTOR
▲CAUTION!
TECHNICAL DATA
MODEL
Power
Speed
Air Capacity
Pressure
Voltage
Support
Oil
Noise Level
Safety valve must be
This compressor is
LJ1500-24
1.5Kw / 2Hp
2850 r.p.m.
264 L/min
8Bar / 116PSI
230V~50Hz
Wheels
No
97dB
equipped with an automatic reset thermal
overload protector, which will shut off motor if it
becomes overheated.
If thermal overload protector shuts motor OFF
frequently, look for the following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
▲CAUTION!
protector is actuated, the motor must be allowed
to cool down before start-up is possible. The
motor will automatically restart without warning
if left plugged into electrical outlet and unit is
turned on.
STORAGE
1. When not in use, store hose and compressor
in a cool dry place.
2. Drain tank of moisture.
3. Disconnect hose and hang open ends down to
allow any moisture to drain.
LJ1500—50
1.5Kw / 2Hp
2850 r.p.m.
264 L/min
8Bar / 116PSI
230V~50Hz
Wheels
No
97dB
6
If the thermal overload
LJ15002-50
3Kw / 4Hp
2850 r.p.m.
528 L/min
8Bar / 116PSI
230V~50Hz
Wheels
No
97dB