3.6 Checks after the first start
Malfunctions of the machine:
•
Pull the power supply plug. Turn the phase changer around 180º at the power supply plug with
a screwdriver.
WARNING!
If machi ne functions are blocked, switch off the machine immediately!
Long operation of the pump in false direction of rotation leads to the total failure
of the pump!
•
Turn the main switch to the right on position "On".
•
Press the button "I" (ON). The button lights up, if the machine is ready
for use.
•
Before pressing the button "R" (RESET) the tools must be
inserted into the machine. Otherwise the button "R" (RESET)
flashes fast.
•
Press the button "R" (RESET). The machine accomplishes an
automatic tool recognition. Keep pressed the button until the
button lights up.
- 29 -
Phase changer