IMPORTANT SAFETY INFORMATION
Installation notes
•
Minimum Clearance from unit to combustible materials:
48" (121.9 cm) from all sides and back. Do not place this fire table under any overhead structure or
vegetation. Do not place on or above combustible surfaces.
•
Save these instructions for future reference. If you are assembling this unit for someone else, give this
manual to them to read and save for future reference.
•
If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury, or death.
•
Installation and service must be performed by a qualified service agency or gas supplier. Real Flame
recommends using professionals who are certified in the U.S. by the National Fireplace Institute® (NFI)
as NFI Gas Specialists.
•
The normal LP inlet pressure for this appliance is 11.0" W.C. (2.74 kPa), maximum inlet pressure is 13.0"
W.C. (3.23 kPa), minimum inlet pressure is 8" W.C. (1.99 kPa).
•
Do not remove the feet from the fire table.
•
Do not place the fire table on anything that blocks or seals the gap between the table and the ground.
•
Do not permanently secure the fire table in any way or to any surfaces.
•
Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
•
Do not coil or hide the hose under the fire table. The hose could be damaged if it touches hot
surfaces.
General Warnings
•
Children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
•
Young children should be carefully supervised when in the area of the fire table.
•
Clothing or other flammable materials should not be hung from the fire table or placed on or near
the appliance.
•
Any guard or other protective device removed for servicing the fire table must be replaced prior to
operating the appliance.
•
Installation and repair should be done by a qualified service person. The fire table should be
inspected before use and at least annually by a qualified service person. More frequent cleaning
may be required as necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the appliance are kept clean.
•
Do not store or use gasoline or other flammable vapors or liquids within 25 feet ( 7.62 m) of this or
any other appliance.
•
Do not store combustible materials in the fire table enclosure. This includes LP tanks. If the fire table
is designed to use a hidden LP tank, the LP tank should be properly secured in the designated tank
holder under the table. Do not store extra LP tanks under the fire table.
•
Be sure to protect the hose and its components from any hot surfaces. It is dangerous to allow the
hose to come into contact with any hot surface.
•
If using your fire table with a LP tank, the tank should never be operated while on its side or up-side-
down.