6. For users diagnosed with common arrhythmia (atrial or ventricular premature beats or atrial
fibrillation), diabetes, poor circulation of blood, kidney problems, or for users suffered from
stroke, or for unconscious users, the device may have difficulty in determining the proper blood
pressure.
7. To stop operation at any time, press the air release valve, and the air in the cuff will be rapidly
exhausted.
Specifications
Measurement Method
Measurement Range
Pressure Sensor
Accuracy
Inflation
Deflation
Memory capacity
Auto-shut-off
Operation Environment
Storage Environment
Power Source
Dimensions
Weight
Arm circumference
Limited users
K.B.
*Specifications are subject to change without notice.
Warranty
1. This product is guaranteed for 2 years from the date of acquisition and this guarantee is effective
only by presenting the RECEIPT OF PURCHASE stating the buyer's name, date of purchase,
name, and address of the distributor.
2. Only defective products with manufacturing problems are covered by this guarantee. Devices
with malfunctioning problems caused by misuse or improper handling even if not intentionally, are
not covered by guarantee.
3. The guarantee covers the functioning of the monitor with the exception of the cuff because it is a
fragile piece and if handled improperly it can blow up or to be punctured, etc.
4. This guarantee does not cover damages by dropping down the device, direct exposition to high
humidity, water, battery leakage, and the batteries included in the device, repairs executed by
unauthorized person, violation of the device by the customer or by unauthorized person.
5. The guarantee does not cover the cost of round-trip transport for repair, the result or damage
caused by improper use of the device and other expenses not specified here.
6. The guarantee is good only in countries where this product is officially commercialized by the
manufacturer or the local distributor and authorized by the manufacturer, always with the
presentation of the receipt of the purchase.
7. This is a non-transferable guarantee; it means it is good for the first consumer only.
8. During the period of this warranty the producer is obligatory to repair the product 30 days from
the date of receiving the device for repair.
9. The manufacturer reserves the right to replace the defective product by a new one in case of
need and decision of the manufacturer.
10. All repairs executed during the period of warranty do not extend the deadline of the guarantee.
11. After the guarantee is expired, the manufacturer has to manage to reserve components and to
supply technical assistance during 5 years in order to offer paid-services to users.
All manuals and user guides at all-guides.com
: Oscillometric
: Pressure: 40~250 mmHg; Pulse: 40~180 beats/ minute
: Semi conductor
: Pressure: ± 3 mmHg; Pulse: ± 5% of reading
: Pump Driven
: Automatic Pressure Release Valve
: 90-set memory
: 1 minute after last button operation
: 10°C~40°C (50°F~104°F); 40%~85% RH max.
: -10°C~60°C (14°F~140°F); 10%~95% RH max.
: 6VDC, four R06 (AA) batteries
: 137 (L) X 140 (W) X 64 (H) mm
: 400 g (G.W) (w/o Batteries)
: Adult: 24~36 cm (9,4"~14,2")
: Adult users
: Short time operation 2 minutes.
: Type BF
Device and cuff are designed to provide special protection against
electrical shocks.