7
Troubleshooting
Fault
People/vehicle separation does not work as expected
Late detection of traffic
Door reverses (sensor reacts to closing door)
Door opens without motion of a vehicle (or person)
Door does not activate though sensors signals detection (LEDs)
Late detection or non-detection of people
Door stays open
8
Technical data
Technology
Transmitting frequency
Transmitting power
Operating voltage
Operating current
Temperature range
Air humidity
Mounting height
Relay outputs
Switching voltage
Switching current
9
Conformities
9.1
EC-Declaration of Conformity
Manufacturer:
Following directives have been observed:
Product variant
9.2
FCC approval
This device meets the requirements of Part 15 of the FCC regula-
tions and the RSS-210 standard of Industry Canada.
10
Warranty and liability
1. The warranty and liability of Bircher Reglomat AG are based on the sales con-
tract.
2. The warranty and liability shall expire prematurely, should the client or third
parties not use and/or operate the product in compliance with existing opera-
ting instructions, should incorrect changes or repairs be made by the client or
third parties, should the client or third parties, when a fault has occurred, not
take suitable steps at once for a reduction of possible damage/losses and offer
Bircher Reglomat AG a chance for remedying the said fault.
3. The warranty and liability shall exclude any damage for which there is no proof
that it is due to poor materials, faulty construction, poor workmanship, and any
11
Contact
Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
www.bircher-reglomat.com
8
Doppler radar with planar module
24.05–24.25 GHz
< 20 dBm
12–28 VAC, 12–36 VDC (45-65 Hz)
max 75 mA
–30° bis 60° C
0% to 95% relative,
without condensation
2 to 7 m
Potential-free changeover contacts
max 48 VAC/DC
max 0.5 A AC
Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen
RoHS 2011/65/EU, RED 2014/53/EU
Herkules 2E
Remedy
Check mounting height & setting (recommended > 3 m)
Check mounting situation & environment (best: sensor centered above door)
Check setting/clip for wide field pattern
Increase field size/sensitivity
Adjust inclination angle to move the pattern away from the door
Adjust inclination angle to move the pattern away from the door
Reduce field size/sensitivity
Make sure sensor is tightly fixed and its mounting support does not vibrate
Mount sensor away from EMC interference (e.g. fluorescent tubes, HID lamps,
wireless system, motor/inverter, etc.)
Point pattern away from EMC interference
Activate interference filter
Check wire colors against output selection
Reduce mounting height (recommended < 5 m)
Change output logic
Housing
Dimensions
Weight
Protection class (EN 60529)
Max. detection speed
Cable
Suitable for the following
countries
Warning: Changes or modifications made to this equipment not
expressly approved by Bircher Reglomat AG may void the FCC
authorisation to operate this equipment.
damage caused by other reasons, for which Bircher Reglomat AG cannot be held
liable.
4. No liability can be assumed for any consequential damage, provided this is not
governed otherwise by applicable product liability laws and regulations.
5. Warranty claims made against the seller on the basis of the sales agreement
are not affected by these regulations.
6. For the benefit of its customers Bircher Reglomat AG constantly develops its
products further. Bircher Reglomat AG reserves the right to make changes to any
of the products described in this document without prior notice.
Aluminium black anodized,
Cover Polycarbonat
134 x 82 x 75 mm
820 g incl. cable
IP 65
25 km/h for vehicles
Length 10 m, 6 x 0.20 mm
2
EU, EFTA, US, CA