Bircher Reglomat Herkules 2E Traducción Del Manual De Instrucción Original página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
4.3
Establishing Connection to the Sensor
The RegloBeam 2 functions bidirectionally with the sensor. This means
that changes to the settings on the sensor are immediately signalled
back by the sensor to the remote control. If an additional parameter is
Ensure sensor is in
programming mode
(section 5.1)
Once
blinks, press
again to establish
connection.
i
Note: If any buttons are blinking, programming failed. In this case, repeat programming.
5
Functions & Settings - Programming by Remote Control
5.1
Establishing Connection to the Sensor
The connection between the RegloBeam 2 and Herkules 2E can only be
established when the sensor is in programming mode (unlocked). Pro-
gramming mode is activated when the sensor is switched on. For sa-
Programming mode can be activated in three different ways:
A) Restart the sensor
(temporarily disconnect the supply voltage)
C) Enter access code with remote control
Press
to establish connection to the
sensor. The sensor address will illuminate.
4
The sensor's address
Choose function to be
illuminates on the
programmed. See
keypad.
chart on following
pages for complete
EXAMPLE:
list.
address 
(factory setting)
Press the desired
function (letter)
button.
EXAMPLE:
mounting height
1
2
Press
4-digit preset access code, followed by
EXAMPLE:
    
Sensor is now in programming mode.
programmed within 2 minutes of the previous parameter, it is not ne-
cessary to press
time.
The sensor acknow-
ledges it's current
setting by illuminating
it on the keypad.
EXAMPLE:
 = 4 – 5 m
(factory default)
fety reasons, this mode is automatically deactivated 30 minutes after
the last setting has been made on the sensor. The sensor can be locked
at any time by pressing
B) B riefly press one of the buttons inside the sensor unit,
L or R
To access programming buttons, open the front cover of the sensor
by removing 4 screws.
Replace cover and close securely once button has been pressed.
followed by  and enter the
to re-establish connection to the sensor each
Now press desired
The new setting is
new value.
immediately saved and
displayed on the
EXAMPLE:
keypad.
Desired height = 3 m
Choose  = 3 – 4 m
Programming of this
function is now
complete. Repeat for
other functions if
necessary.
 followed by  .
If parameters cannot be changed (buttons
blink), repeat sequence.
.
If connection is still not established,
use option A or B above (no access code
was previously stored.)
Tabla de contenido
loading

Productos relacionados para Bircher Reglomat Herkules 2E

Tabla de contenido