7 Technical data
7.1 Data of the motor test bench
General information
Dimensions (H x W x D in mm)
Weight
Ambient conditions
Device operation
Noise level
Rotational speed setting range
Torque setting range
Braking power
Duty cycle for mechanical nominal power
Subject to technical change
Electrical components
Supply voltage
Input frequency
Device fuse
Input power
Increased leakage current:
Protection class
Overvoltage category
Pollution degree
Test specimen connection field
Voltage measurement
Current measurement
Switching output error
Temperature switch input
USB port
Control circuit
Primary circuit
Subject to technical change
© Festo Didactic 8121048
510 x 380 x 270 mm
22 kg
5 – 40 °C, relative humidity up to 65%, non-condensing
For indoor use only up to 2000 m above sea level
< 80 dB
-4000...+4000 rpm
-4... 4 Nm
Max. 400 W, 250 W nominal power
Max. 50% at 20 °C within a period of 3 h
110–230 V AC ±10 %
50...60 Hz
6.3 A slow-blow
800 W
≤ 8 mA
1, operation with protective grounding
Second protective grounding conductor must be connected!
II, operation in building installations
2, laboratory environment
L1/L2/L3
400 V AC/5 A
L1/L3; L1/N; DC+/DC-
400 V AC or 250 V DC
L1/DC+ input L1/DC+ output, 5 A AC/8 A DC
30 V/1 A
24 V DC/0.1 A
USB-B 2.0
Black bushings,
24 V DC
Gray bushings,
400 V AC or 250 V DC
Servo brake and drive system
59