Other Operation
a. External & Internal Temperature Check:
Long press the '
' and '
' to switch the internal temperature
or the external temperature.
b. Temperature Protection Warning:
When the temperature is higher or lower than the protection
value, '
' will flash, the valve will auto close or open, and
adjust the temperature to 2℃ lower or 2℃ higher than the
protection value, '
' will stop flash and the protection mode
cancelled.
c. ERR Exception :
When the '
' light up, it means the sensor mode was wrong or
the sensor was broken. And the temperature value in the screen
will show ' -- ' .
d. There have the Valve Anti-lock Function.
Advanced Settings
When the thermostat is power on, long press the '
press '
' select the setting items, and press '
1 Sensor type
00: Internal 01: External 02: Internal & External. Default is 00
2 High temperature protection:
20~90℃, Default is 28℃, ' -- ' Cancel the protection
3 Low temperature protection :
0~15℃, Default is 5℃, ' -- ' Cancel the protection
1-9 ℃, Default 2 ℃
Swing:
4
Temperature calibration :
-9℃~+9℃, Default is 0℃
5
Highest target temperature:
6
Lowest target temperature:
7
Home mode target temperature:
8
Away mode target temperature:
9
AUTO mode target temperature:
10
11
System restart:
Press ' ' or ' ' to switch the ' -- ' to ' == ' and wait for 5s
12
Factory setting:
Press ' ' or ' ' to switch the ' -- ' to ' == ' and wait for 5s
' (5s),
' and '
' or '
' to select.
35~90℃, Default is 35℃
0~30 ℃, Default is 5℃
Default is 22℃
Default is 15℃
Default is 20℃
09