RRC SMB-UBC Manual De Empleo página 2

Manual
RRC-SMB-UBC
.en
The smart battery charger is used to charge SMBUS batteries (Smart Batteries) with form factors
RRC2020, 2024, 2040 or smart batteries with a similar footprint e.g. 202x range, 204x range, 205x
Introduction:
range, DR36, etc..
Only batteries that comply with the Data Specification 1.0 or 1.1 can be charged with this battery
Caution:
charger. Other rechargeable batteries or conventional batteries may not be used.
Use smart batteries for as long as possible in your device before recharging. The more completely they
Tip:
are discharged, the more exact the charger can calculate capacity and charge requirements.
Making Connections
1.
Connect the cable from the mains adapter to the battery charger.
2.
Connect the power cable to the mains adapter and plug it into the mains socket.
3.
The LED is going out after the selftest of the battery charger. The battery charger is ready for use.
4.
If the red control lamp remains on and no battery is in the charger, the battery charger is defective.
Charging Batteries
1.
Connect up the battery charger as described above.
2.
Place a discharged Smart Battery into the battery charger.
3.
The battery charger makes a battery recognition and intialisation.
4.
The battery will be charged. Leave the battery until the green control lamp lights.
5.
Then the battery is fully charged. Remove the battery for use.
Usage of spacer
So that the battery RRC2020 or one with a similar form factor can be used, the spacer shown below (Figure 1) must be
used. The spacer is inserted like in figure 2 & 3 until it snaps. After that, the battery can be inserted for charging (Figure
4). For the use of other battery types the spacer must be removed again.
Figure 1
Figure 2
LED Indications
One time Red/Orange/Green
Self test: Charger is ready for use.
The battery was not recognised as a Smart Battery. Either a conventional
battery is inserted or an extremely discharged Smart Battery. If it is a Smart
Red/Green blinking
Battery, it will be reactivated within 15 minutes and recharged. If this is not
the case, the LED will light red – see below.
Orange blinking
The battery is currently being calibrated.
Orange light
The inserted battery is the correct type and is currently being charged.
Green light
The battery is charged and can be removed for use.
The battery is too hot or too cold to be charged without damage. If the battery
Red blinking
is too cold it will be charged as soon as it has warmed up sufficiently. If the
battery is too hot it should be removed to cool down.
Either
Red light
- the battery is badly damaged and must be replaced, or
- it is a conventional battery which cannot be recharged.
E
2
NGLISH
Figure 3
Figure 4
Manual
RRC-SMB-UBC
.en
This battery charger may not be located in the vicinity of a patient.
In accordance with EN60601-1-1, the horizontal distance must be at least 1.5 meters.
Do not insert a fully charged battery into the charger repeatedly. Due to the high initial
charge, the battery could be overcharged which could lead to damage to the battery and to
the battery charger
Use the battery charger only in dry indoor environments! Wet and moisture covered products
should not be used!
This product has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
FCC Advice,
accordance with the instructions, may cause harmful interference to radio communications.
valid in USA
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications of the device are not allowed.
Declaration of
The battery charger complies to the current regulations of the EU guidelines.
Conformity:
Symbols
Caution / Warning
Instructions for use
Use only in enclosed spaces
Sign of conformity to the applicable EC Directives
The product should be disposed of according to local guidelines
RoHs (China)
DC voltage
Mark of compliance to the California Energy Commision requirements
Technical Specifications
Battery Charger
19 - 26VDC / 3.4A
Input Voltage
max.
Charging and Output
0 - 17.4VDC / 0 - 4.8A
Voltages
Power
60W
Measurements
151 x 90 x 43mm
(L x B x H)
Operating / Storage
0°C to 40°C / -10°C to
Temperature
70°C
Weight
198g
Safety Standards /
IEC/EN60950-1 UL60950-1* / EN55011 / EN55022 / EN55024* / FCC15 class B /
EMC Standards
IEC/EN61000-4-2,-3,-4,-5,-6,-8,-11* / EN61000-3-2,-3-3*
* valid only for power supply
E
NGLISH
Power Supply
RRC-SMB-UBC
RRC-SMBC-UBC-M
100-240VAC / 50 - 60Hz
100-240VAC / 50 - 60Hz
19VDC ± 5% / 3.4A
19VDC ± 5% / 0 - 3.43A
65W
65W
95 x 51 x 25.4 mm
119 x 60 x 36mm
0°C to 40°C / -10°C to 70°C
0°C to 40°C / -20°C to 80°C
270g
310g
3
which the