Programme Early Warning Alarm
An early warning alarm can be programmed to sound from 1 to 9 wraps
before the target number is reached. For example, if the bale requires 22
wraps and you want an alarm at 20 wraps, then set the number to 2.
To effectively disable the alarm, set the number to 0.
Part and Grand Total
When bale wrap is complete, both part and grand totals automatically
advance by 1. The part total can be reset at any time. The grand total cannot
be reset.
Display totals
Switch the power off.
Hold, switch power on and continue holding.
The fourth digit flashes.
Hold to cycle to the required digit.
Release all.
Press and hold.
Part total displays for 8 seconds
Silacount 200 Bale Wrap Monitor