7.2
Check the application conditions:
8025303.1BBX / 2021-04-27 | SICK
Subject to change without notice
Figure 2: Alignment aid BluePilot
Sensing range
Adjust the distance between the sensor and the reflector according to the correspond‐
ing diagram
[figure
3] (x = sensing range, y = operating reserve).
After alignment, place a non-transparent object into the path of the beam. Check the
function as described in
figure
figure
X, check the application conditions.
Standard reflectors:
Operating reserve
40
35
5
6
30
7
25
4
20
3
15
2
10
5
1
1
0
1
2
3
(3.28)
(6.56)
(9.84)
Figure 3: Characteristic curve for standard
reflectors
Reflector PL22
1
Reflector PL20A
2
Reflector PL30A
3
Reflector PL40A
4
Reflector PL80A
5
Reflector C110A
6
Reflector P250
7
Fine triple reflectors:
X. If the switching output fails to behave as described in
1
0.02
2
0.015
3
0.015
4
0.015
5
0.015
6
0.015
7
0.015
0
(3.28)
A
A = Sensing range min. in m
B = Sensing range max. in m
C = Maximum distance range from reflector to sensor (operating reserve 1)
D = Recommended distance range from reflector to sensor (operating reserve 3.75)
Recommended sensing range for the best performance
Figure 4: Bar graph for standard reflectors
4
5
6
(13.12)
(16.40)
(19.69)
Distance in m (feet)
COMMISSIONING
2.0
3.0
1.9
2.5
3.1
4.5
4.0
5.0
4.5
5.5
4.5
5.5
3.9
4.5
1
2
3
4
5
6
(6.56)
(9.84)
(13.12)
(16.40)
(19.69)
Distance in m (feet)
D
C
B
7
9