AKR 410-412-413-415-416-610-611
AKR 612-613-615-616 / AKG 957
1. Control panel.
2. Grease filters (behind the extractor grille).
3. Lighting unit.
4. Pull-out steam deflector
(not extractable on AKR 610).
REPLACING BULBS
1. Unplug the appliance or disconnect the mains
power supply.
2. Pull out the steam deflector (a-Fig. 1).
3. Open the extractor grille (b,c,d-Fig. 1).
4. Remove the burnt-out bulb. Replace using
40W max E14 bulbs only.
5. Refit the extractor grille.
FITTING OR RENEWING THE CARBON
FILTER:
1. Unplug the appliance or disconnect the mains
power supply.
2. Pull out the steam deflector (a-Fig. 1).
3. Open the extractor grille (b,c,d-Fig. 1).
4. Rectangular or circular carbon filter:
Circular carbon filter - Fig. 2:
Assembly: Fit the carbon filter over the motor
protection grille - The reference mark on the
edge of the carbon filter (e) must align with
the arrow on the fan shroud (f), lastly turn
clockwise.
Disassembly: Turn anticlockwise.
Rectangular carbon filter - Fig. 3:
Assembly: (g) Locate the carbon filter on the
back rings and (h) secure the carbon filter in
front with the clips provided.
Disassembly: Press the release buttons
(f-Fig. 2) and pull the filter downwards.
5. Refit the extractor grille.
REMOVING AND RENEWING OR
CLEANING THE GREASE FILTER:
1. Unplug the appliance or disconnect the mains
power supply.
2. Pull out the steam deflector (a-Fig. 1).
3. Open the extractor grille (b,c,d-Fig. 1).
4. Remove the device securing the grease filter.
5. Remove the dirty grease filter.
6. After the grease filter has been replaced or
cleaned (depending on model), refit the parts
in reverse order, making sure the entire
extraction surface is covered.