green
red
Ton
Cause
LED
LED
e
-
b
6x
• Stop button has been
pressed.
• Power failure
green
red
Ton
Cause
LED
LED
e
-
x
6x
Press tool faulty.
-
x
6x
• Press tool is overloaded.
• Mains voltage too low.
• Dirt or deposits between
jaw levers or in press
profile of press jaw.
To rectify the following faults, always:
- Press Start button (1) until piston is fully retracted.
green
red
Cause
LED
LED
-
b
Start button released before tool
is ready for automatic pressing
(Zwag).
Fault signal before press tool could start:
NOTE
LAST PRESSING (POSSIBLY) NOT OK!
Fault signals after press tool started.
Note
THESE PRESSINGS ARE NOT OK!
Remedy
Do not press Stop button unintentionally. Check
fitting for leakage and, if necessary, carry out
pressing once more.
Remedy
Return press tool to Novopress for inspection.
• Use only permitted materials (see "Intended use").
• Should this fault occur repeatedly in succession,
allow the press tool to cool down fully.
• Check mains voltage.
• Clean press jaw.
Remedy
Keep Start button pressed for a prolonged period
(approx. 2 seconds).