6. Selecting the position of the output spectrum
Inp.
2004 MHz
22,000 MS/s
Outp.
S21
6,111 MS/s
After having selected the parameter „... QAM", press
and go to the sub-menu.
7. Aligning the channel unit
The output level of the channel unit can be adjusted
with the aid of the level adjuster (on front panel). Recom-
mended level range on output of the reception system
UFG 308/312/316: 75...90 dBµV / 75 Ω.
Level measurement requires the use of a QAM capable
signal meter (e. g. MSK 33 from Kathrein).
The measuring instruments from Kathrein mentioned in
the following can also be used, provided that the
corresponding correction values are added to the
displayed value.
Remote power
supply
KATHREIN-Werke KG · Anton-Kathrein-Straße 1–3 · P.O. Box 10 04 44 · 83004 Rosenheim · Germany · Tel. +49 (0) 80 31 18 40 · Fax: +49 (0) 80 31 18 43 06
5/6
306,00 MHz
64 QAM
* * * *
Modulation
Spectrum
<
Back to: sub-menu
Select the parameter „Spectrum" in the sub-menu with
„ " or „ ".
Select the operation mode „normal/inverse" with
„+" or „-".
Signal meter
Type
MFK 50
MFK 55
MFK 85
MSK 31
UFO 387
VHF
VHF
UFO 387
VHF, UHF
UFO 385
* * * *
SAT-Signal
normal
Measuring
Correction value
function
(for 64 QAM; 6,875 MS/s)
F5
F94
UFO 387
VHF
UFO 385
>
+ 0,5 dB
+ 0,5 dB
+ 2 dB
Control unit