When an alarm sounds:
The display will flash and the alarm message will appear as in the table below.
The machine will stop if necessary
Important note: any work must be done by qualified person.
The alarm is cancelled automatically when the fault is cleared
CODE
AL
Temperature below the minimum limiter of the set point
AH
Temperature above the minimum limiter of the set point
E1
Probe has short-circuited, circuit opened
EE
Memory error
HPE0801
Power supply disconnected.
Water pump out of order, short circuited or disconnected.
PUMP
OFF
HPE1001 / HPE1301 / HPE1303 / HPE1703 / HPE2203
Power supply disconnected.
Display OK + compressor OFF = no water flow and water flow presence light out..
(M1 + M2) "OFF"
All models
+ L1 "ON"
HP / BP failure
+ Set point > T°
Check the pressure switch electrical connection
Water
Call a specialist.
HPE0801 / HPE1001 / HPE1301 / HPE1303 / HPE1703 / HPE2203
Functioning out of the T° operating limits
Without "low T° kit":
= External T° < à 5°C
INSUFFICIENT
DE-ICING
With "low T° kit" :
= External T° < à 5°C
Evaporator clogged.
Lack of coolant fluid
THD default, defrost thermostat out of order or disconnected.
Password required (Only for the pool builder or anybody in charge of maintenance and/or
PA
repair)
ALARMS
OPERATING MESSAGES
DESCRIPTION
22