SD/SV Series Submersible Pumps
Maintenance
Check pressure, output, voltage, current and other specifications. Unusual readings may indicate.
Refer to Troubleshooting and correct as soon as possible.
Daily inspections
1.
(1)
Check current and ammeter fluctuation daily. If ammeter fluctuation is great, even though
within the limits of pump rating, foreign matter may be clogging the pump. If the quantity of liquid
discharged falls suddenly, foreign matter may be blocking the suction inlet.
2. Regular inspections
(1)
Monthly inspections
Measure the insulation resistance. The value should be more than
fall rapidly even with an initial indication of over 1M ohm, this nay be an indication of trouble and
repair work is required.
(2)
Annual inspections
To prolong the service life of the mechanical seal by replacing the oil in the mechanical seal
chamber once a year. Water mixed the oil or cloudy textures are indications of a defective
mechanical seal requiring replacement. When replacing the oil, lay the pump on its side with filler
plug on top. Inject suitable amount turbine oil No.32 (ISO VG-32)
.
(3)
Inspections at 3-5year intervals
Conduct an overhaul of the pump. These intervals will preclude the possibility of future trouble.
. Parts that will need to be replaced
3
Replace the appropriate part when the following conditions are apparent.
Replaceable part
Replacement guide
chamber is clouded
Frequency
Note: above replacement schedule is based on normal operating conditions
Motor output
Part
Mechanical seal
Oil seal
Oil filler plug gasket
Lubricating oil
(turbine oil #32)
Mechanical seal
Oil filler plug O-ring
Whenever oil in
Whenever oil is
mechanical seal
Annually
A half yearly
0.4kw / 0.75kw
Φ15
Φ23
Φ35
x
(Inner diameter) x (outer diameter) x (Wire diameter)
140 cc
Lubricating oil
Whenever clouded
replaced or
or dirty
Inspected
A half yearly
1.5kw / 2.2kw / 3.7kw
7
x
5
1M ohm
. If resistance starts to
O-ring
Whenever pump is
overhauled
Annually
.
Φ20
Φ30
Φ45
7
x
x
(Φ4.8x Φ8.6xΦ1.9)
=
340 cc