Tabla de contenido
RAID-subsysteem DVA-08E, -08K, -16K
2.2.2

Systeeminstellingen

Menu
Configuration Parameters/Communication
LAN 0
IP Address
Subnet LAN 0
Configuration Parameters/Caching
Write-Back Cache
Optimization
Periodic Cache Flush Time (sec)
Configuration Parameters/Host Side
Maximum Queued I/O Count
LUNs per Host ID
Maximum Concurrent Host-LUN Connection
Tags Reserved per Host-LUN Connection
Peripheral Device Type
Peripheral Device Qualifier
Device Supports Removable Media
LUN Applicability
Cylinder/Head/Sector Ranges
Configuration Parameters/Drive Side
Disk Access Delay Time (sec)
Drive I/O Timeout (sec)
Maximum Tag Count
Periodic Drive Check Time (sec)
Periodic SAF-TE/SES Device Check Time (sec) 30
Periodic Auto-Detect Failure Drive Swap
Check Time (sec)
Drive Predictable Failure Mode (SMART)
Auto-Assign Global Spare Drive
Drive Spindown Idle Delay Period (sec)
Drive Delayed Write
Configuration Parameters/Disk Array
Rebuild Priority
Verification on LD Initialization Writes
Verification on LD Rebuild Writes
Verification on Normal Drive Writes
AV Optimization Mode
Maximum Drive Response Timeout (msec)
Bosch Security Systems
Beknopte installatiehandleiding
Afleveringsstatus | nl 207
DVA-08E / DVA-08K / DVA-16K
Static IP Address
10.11.12.13
255.0.0.0
Enabled
Sequential I/O
30
256
8
1024 (4 Default)
4 (32 Default)
No Device Present (Type = 0x7F)
Connected
Disabled
All Undefined LUNs
Variable/Variable/Variable
25
7 (Default)
4
1
5
Detect Only
Enabled
Disabled
Enabled
Normal
Disabled
Disabled
Disabled
Fewer Streaming
160 (Default Disabled)
F.01U.027.800 | V4 | 2008.08
Tabla de contenido
loading

Este manual también es adecuado para:

Dva-08kDva-16k

Tabla de contenido