IFM Electronic AC016S Instrucciones De Uso Originales página 17

Amplificador electrónico para detector de seguridad con as-interfaz
Ocultar thumbs Ver también para AC016S:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
LED
Colour State
1
yellow
2
red
3
4
red
5
yellow
PWR
green
AUX
green
Setup
Electrical connection
The supply of the fail-safe switches comes from the AS-i
system. Do not connect the inputs with an external potential.
Connect the M12 socket I-1 of the evaluation unit to the
corresponding connections of the fail-safe switch or the chain of fail-
safe switches (L+, TE, L- and OUT).
on
on
flashing
on
on
on
on
Meaning
fail-safe switch or chain enabled
FAULT
AS-i communication error
slave does not participate in the
"normal" exchange of data, e.g.
if slave address = 0
periphery fault, e.g. sensor
supply overloaded or shorted
infrared receiver
initialisation phase up to first
enabling
or error in the evaluation
(ERROR)
unsafe switching output O-3
logically on
AS-i supply voltage ok
external supply voltage ok
17
Tabla de contenido
loading