Main Technical Features - Kübler CODIX 130 Manual De Instrucciones

Ocultar thumbs Ver también para CODIX 130:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Main technical features:

Display:
LCD, 8 decades, height of the figures 8 mm.
Display range:
-9999999 ... 99999999
with leading zeros suppression.
Overflow: In case of a display range overflow, the
counter starts again from 0, but without
removing the leading zeros and activating
all decimal points.
In case of a display range underflow, the
counter starts again from 0 and displays the
minus sign, without removing the leading
zeros and activating all decimal points.
Keys:
Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
+0,3
+0,6
22,2
x 45
Mounting depth: approximately 48 mm
Weight:
approximately 50 g
Protection level:
IP65 on the front side
Input specification, pin assignment and adjustable operating modes (DC versions).
A control input (screw terminal 5) allows adjusting the operating mode.
Screw terminal
Nr. 1
Designation
INP A
Model
6.130.012.8x0
07 kHz
6.130.012.8x2
12 kHz
6.131.012.8x0
07 kHz
6.131.012.8x1
12 kHz
6.133.012.8x0
03 kHz
6.133.012.8x1
06 kHz
Table 2
Screw terminals 1 and 2:
Function and max. frequences(Pulse/Pause 1:1)
see Table 2
NPN :
active for negative edge
Input resistance:
approximately 1 MOhm
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
6
mm
Nr. 2
INP B
NPN
30 Hz
NPN
PNP
NPN
NPN
07 kHz
NPN
PNP
12 kHz
PNP
NPN
03 kHz
NPN
PNP
06 kHz
PNP
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: 4,0 mm
Connection diameter:
EMC:
Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Low Voltage Directive (for the AC models):
EN 61010 Part 1 ; overvoltage category 2,
contamination level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately, 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 ... +70°C
Backlighting:
external electrical source
(24 V DC ±20 %, 50 mA)
Nr. 3
Nr. 4
Nr. 5
Reset Reset
Control inputs for operating
Enable
not active
=
adding
not active
=
Cnt.Dr Mode
not active
=
Quad Mode
PNP :
Input resistance:
Low level:
High level:
2,5 mm
AWG 12
0,4 ... 2,3 mm single-wire
AWG 28-12
Nr. 6 Nr. 7
GND
mode (Mode)
contact with
GND =
subtracting
contact with
GND =
Up.Dn Mode
contact with
GND =
Quad2 Mode
active for positive edge
approximately. 100 kOhm
0 .. 0,7 V DC
4 .. 30 V DC
2
single-wire
2
thin wire
Nr. 8
BL
BL
+
Tabla de contenido
loading

Este manual también es adecuado para:

Codix 131Codix 132Codix 133

Tabla de contenido