Maintenance
Problems
Signals
PRESET
POWER
will not turn on
STATUS
POWER
STATUS
POWER
STATUS
POWER
STATUS
POWER
The pump will
STATUS
not start when
a tap is turned on
POWER
STATUS
POWER
STATUS
The pump
POWER
delivers no or low
STATUS
pressure
The pump stops
POWER
and starts
STATUS
repeatedly
POWER
The pump will
STATUS
not stop
= ON
= OFF
Exploded view of spare
parts
Attention: when ordering
spare parts, always state
the position n° from the
diagram below and the
product code number
found in the pressure-flow
regulator technical data
table.
50066/115
CODE:
V / Hz:
230 / 50 - 60
I max:
16 A
1.5 Bar
P start:
B
2008
Year:
Possible causes
A - No power
B1 - The restart pressure (Pm)
P 2.3
setting is unsuitable to the type of
installation.
B2 - Faulty electrical connections or
P 2.1
pump out of service
STOP
B3 - PRESET "OUT OF SERVICE"
B4-1 - PRESET in temporary shut
down due to "DRY RUNNING" due to
lack of water
RY RU
B4-2 - Maximum pump pressure is
DRY RUNNING
insufficient
AKAGE
B5 - PRESET in temporary shut down
due to "FREQUENT START-UP"
LEAKAGE
VERLO
B6 - PRESET stops due to "OVER-
CURRENT"
OVERLOAD
C-1 - Filters or pipes may be partly
blocked
P 2.8
C-2 - PRESET's valve will not open
completely
D - Leaks within the system (less
POWER
than the shut-off flow rate Qa)
STATUS
E-1 - The flow rate is higher than the
shut-off flow rate (Qa)
P_3.7
E-2 - PRESET's check valve will not
close
5
1
3
2
4
1 - Circuit board cover
2 - Sensor kit
3 - Circuit board
Article
4 - Valve kit
5 - Gasket
6 - Back cover
Version
7 - Cable bushings
= Flashing
6
Dimensions
130
7
M 1"
Solutions
A - Check the electrical connections
B1 - Set the Pm at a higher value.
B2 - Check the electrical connections
and that the pump is working
B3 - Reset PRESET
(See Operation, point 3).
B4-1 - Wait for the automatic restart or press
START to restart manually (See Operation, point 4a)
B4-2-1 - Replace the pump with one with more
suitable characteristics
B4-2-2 - Set Pm at a lower value
B5 - Wait for the automatic restart or press START
to restart manually (See Operation, point 4b).
Remove any cause of leakage from system or
install an expansion tank
B6 - Check if the setting of the maximum current
(Imax) is congruent with the data of the pumps'
rating plate. If after manually restarting the pump
after correctly setting PRESET, it again signals an
anomaly, check that the motor has no mechanical
or electrical problems.
C-1 - Check the water pipes
C-2 - Check that the valve is not blocked by any
foreign objects and clean if necessary
D - Check the hydraulic connections and repair
any leaks.
E-1 - Make sure that all taps are turned off and
that there are no leaks within the system
E-2 - Check that the valve is not blocked by any
foreign objects and clean if necessary
P 3.4
= System pressure
174
M 1"
Disposal
When disposing of any
PRESET parts, adhere
to the relevant laws and
regulations in force in
the country in which
the equipment is being
used. Do not dispose of
any polluting
parts in the
environment.