The LED next to the DIP switches indicates the status of the DMX signal:
LED flashing: DMX signal
LED off: no DMX signal
d. Channel Configuration
CHANNEL 1: 7 colours + white
CHANNEL 2: Dimmer
CHANNEL 3: Stroboscope
e. Detailed DMX Values per Channel
CHANNEL 1
CHANNEL 2
CHANNEL 3
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
7. Technical Specifications
Power Supply
Consumption
Fuse
Lamp Type
Dimensions
Weight
Max. Ambient Temperature
The information in this manual is subject to change without prior notice.
VDP250CC3
Description
From
17
34
51
68
Colour wheel 1
85
102
119
136
224
240
Dimmer
15
Stroboscope
20
251
max. 230VAC / 50Hz
max. 260W
8A, 250VAC (5 x 20mm) (order code FF8N)
1 x MSD 250W/94V GY9.5 (LAMP250MSD, LAMP250MSD/2 or
LAMP250MSD/2SYL, not incl.)
315 x 270 x 285mm
8.5kg
45°C
To
0
16
White
33
Red
50
Yellow
68
Purple
84
Green
101
Orange
118
Blue
135
Pink
223
Colour rainbow
239
Red
255
Red / White
0
255
Dimming function
0
14
Shutter closed
29
Shutter open
250
Stroboscope (slow > fast)
255
Shutter open
4
Function
VELLEMAN