TechGrow T-1 PRO Manual De Instrucciones página 14

Ocultar thumbs Ver también para T-1 PRO:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Setting dosing delay:
Start your controller again.
After a few seconds the following screen will
show:
=> System settings
CO2 calibration
Place the cursor at the "System Settings" and
press the DDK:
LCD on-time
CO2 sensor
=> Delay/dose
>> NEXT >>
Move the cursor to "Delay / Dose" and press the
DDK:
=> Delay time
Dose time
<< BACK <<
Move the cursor to "delay time" and press the
DDK: here you can specify how long the controller
must wait before dosing begins after detecting the
light in your room.
Delay time
=> Dose time
<< BACK <<
With the Dose Time function you can determine
how long the dosage remains active.
Example:
Your backlight turns ON from 11:00 until 23:00,
delay time (delay) stands at 30m.
30 min after your light cell has detected light, the
T- 1 will regulate the value, the value of CO2 in
the space.
Dose time (dosage) is at 11 am The CO2 will be
arranged in the space of 11.30 to (+ 11h) 22:30
If this feature is enabled you will see the following
on your screen.
CO2 =
456
CO2 set
700
CO2 +/-
50
Mode Dawn
00:03:20
30s
2000
15m
Off
30m
11h
The bottom line of your controller will alternately
display the following information:
• Min 456 Max 667
• Mode Dawn 00:14:24
• CO2 counter 00:26:15
Right in the corner an hourglass appears, indicat-
ing that the controller is decelerating.
Thereafter, this line will change in
• Min 456 Max 667
• Mode Day 10:59:24
• CO2 counter 00:26:15
Right in the corner a star appears indicating that
the controller is regulating.
Set a 2.000ppm or 10.000ppm sensor.
Start your controller again
After a few seconds the following screen
appears:
=> System settings
CO2 calibration
place the cursor at the "System Settings" and
press DDK:
LCD on-time
=> CO2 sensor
Delay/dose
>> NEXT >>
place the cursor on "CO2 sensor" and press the
DDK:
LCD on-time
=> CO2 sensor
10000
Delay/dose
>> NEXT >>
Here you can select which sensor you want to
use. Default is set to 2.000 ppm.
BE AWARE:
If you wish to use this feature, you must purchase
a sensor capable of measuring up to 10,000 ppm.
If you enable this function with the wrong sensor,
the controller will display the wrong values and
can damage your controller and sensor.
Your controller is now suitable for measuring and
regulating from 300 to 10,000 ppm. in steps of 50
ppm
30s
2000
30s
Tabla de contenido
loading

Tabla de contenido