Introduction; Application; General Specifications - Exlar EXP-24 Manual De Instalación Y Servicio

Tabla de contenido

Introduction

This manual covers operation, installation and maintenance instructions for the EXP-24 Controller
Manufactured by Exlar Corporation. For Actuator / Motor installation refer to the corresponding manual,
for example EL100 Actuator Installation manual, Exlar PN 44465.

Application

The EXP-24 is designed to meet general industrial motion control requirements for high temperature
hazardous locations. Typical applications include gas turbine guide vane and valve motion control.

General Specifications

The controller is designed to be used specifically with the EL100 Actuator but can be used to drive most
three phase linear actuators and rotary motors with similar ratings. Contact Exlar engineering
regarding alternative actuator and controller combinations.
Input Voltage
Input Current, DC
Output Current, 3Φ
Digital Inputs
Digital Outputs
Analog Input
Analog Output
Serial Interface
Commutation
Position Feedback
Environmental
Enclosure
N. A. Certifications
E. U. Compliance
EMC
Approx. Weight
EXP 24 Manual
PN 47676
Revision H
Controller Specifications
18 to 32 VDC
30 A Peak, 25 A Continuous
30 A (21 ARMS) Peak, 25 A (18 ARMS) Continuous
2 – Isolated, 18 to 32 VDC
2 – Isolated, 18 to 32 VDC, 250 mA Continuous
1 – Non-Isolated, 4 to 20 mA, 500 Ω Input Impedance
2 – Isolated, 4 to 20 mA, 200 Ω to 500 Ω Driving Capability
Isolated RS-485, Modbus Protocol, Max. Baud Rate 38.4k
Sinusoidal, Space Vector PWM, 10 kHz
Resolver
-29 to 82 °C Operating Temperature Range
-55 to 82 °C Storage Temperature Range
IP 66, NEMA Type 4
CSA Class I Div 1 Group B,C,D,T5
94/9/EC Potentially Explosive Atmospheres (ATEX) Ex d II B, T5
Immunity: EN 61000-6-2: 2005, Emission: EN 61000-6-4: 2007
33 lb (15 kg)
30
1/9/14
Exlar Corporation
952-500-6200
Tabla de contenido
loading

Tabla de contenido