Installation
Trim set installation
- Finish plaster wall and tile up to the fitting template.
When doing so, seal wall openings against water
splashes.
In the case of tiles laid in mortar, pointing must be
bevelled outwards.
• In the case of prefabricated walls, seal with
elastic sealing compounds.
- Remove fitting template (A), see fig. [1].
Mounting escutcheon, see figs. [1] and [2].
1. Push sleeve (B) with the mark (C) upward onto the
mixer shank, make sure that the marking point (C1)
snaps into the sleeve (B), see fig. [1].
2. Grease seal (D) with the grease provided.
3. Slide the escutcheon (E) over the sleeve (B),
see fig. [2].
4. Slide snap inserts (G) over screws (H) and secure
escutcheon (E) to the valve.
Do not use excessive force to tighten the screws.
5. Cover the srews with cover caps (J).
6. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting depth can
be increased by 27,5mm (1 1/8") with extension set
Part No. 47 328, see fold-out page II.
Adjustment
Temperature setting, see figs. [3] and [4].
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies
from the specified temperature set on the thermostat
handle.
• After each service on the thermostat mixer.
1. Open volume control (K) and measure the temperature
of the water emerging with a thermometer, see fig. [3].
2. Turn the green regulator nut (L) clockwise - counter-
clockwise with a screwdriver until the water emerging
has reached a temperature of 100
3. Fit the thermostat handle (M) so that the 100
ƒ
(38
C) mark on the thermostat handle lines up with the
mark (C) on the sleeve (B), see fig. [4].
4. Insert fixing ring (N).
5. Push on handle (O) and screw on handle cap (P).
Reversed union (hot on right - cold on left).
Replace thermoelement (47 450)
replacement parts fold-out page II, ref. No.: 47 282 (1/2")
and 47 379 (3/4").
.
Temperature limitation
When in proper calibration, the temperature range is
ƒ
ƒ
limited to 110
F (43
C). There is a safety check
ƒ
ƒ
at 100
F (38
C).
If a higher temperature is desired, one can
ƒ
ƒ
exceed 100
F (38
C) by overriding the safety check.
1
English
Prevention of frost damage
When the domestic water system is drained, the
thermostat mixers must be drained separately, since
check valves are installed in the hot and cold water
connections.
The complete thermostat assembly and check valves
must be unscrewed and removed.
Maintenance
For Maintenance, see fig. [5], [6] and fold-out page II.
I. Thermostat cartridge
1. Turn thermostat handle (47 570, 47 572) to the 100
2. Remove handle cap (P) and handle (09 698).
3. Take out fixing ring (N).
4. Pull off thermostat handle (M).
5. Pull sleeve (B) from the mixer shank by pressing
6. Extract clamp (S).
7. Pull stop ring (T) until resistance is encountered
8. Unscrew stop ring (T) complete with regulator nut (L).
9. Remove escutcheon (47 492), see fig. [2] and
10. Close both service stops (47 017, 47 467), see fold-
11. Unscrew thermostat cartridge (47 450, 47 582) with
Reassembly should be carried out in reverse order.
Temperature adjustment is necessary after each service of
the thermostat cartridge (see Adjustment).
II. Check valve
1. Proceed as for maintenance of thermostat cartridge,
points 1 - 4 and 9 - 10.
ƒ
ƒ
2. Unscrew check valve (14 116, 47 466) with 17mm
F (38
C).
ƒ
(11/16") socket wrench or 10mm (3/8") allen key.
F
Reassembly should be carried out in reverse order.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012)
or (47 582)
, see
Only original Grohe replacement parts may be used!
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this thermostat mixer will be found
in the Limited Warranty supplement.
ƒ
(38
C) safety check, see fold-out page II.
down the tongue (R), see fig. [5].
(approximately 10mm [3/8"]), see fig. [6].
installation on page 1, Points 3 - 5, in reverse order.
out page II.
24mm (15/16") open-ended wrench.
ƒ
F