976160.book : I97616us.fm Seite 1 Mittwoch, Juni 20, 2001 2:34 PM
Installation
- Finish plaster wall and tile up to the fitting template. When
doing so, seal wall openings against water splashes.
• In the case of tiles laid in mortar, pointing must be
bevelled outwards.
• In the case of prefabricated walls, seal with elastic sealing
compounds.
- Remove fitting template (Y), see fold-out page I, fig. [1].
Fit escutcheon, see figs. [1] and [2].
1. Push sleeve (A) with the mark (B) upward onto mixer shank,
make sure that the marking point (B1) snaps into the
sleeve (A), see fig. [1].
2. Fit escutcheon (C) on the mixer, grease seal (D) with the
grease provided and slide onto the sleeve (A). Secure with
screws (F), see fig. [2].
3. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting depth can be
increased by 1 1/8" (27.5mm) with extension set
Part No. 47 328, see fold-out page II.
If the thermostat is installed too shallow, the fitting depth
can be reduced by 1/2" (12mm) with a spacer Part No. 47 347,
see fold-out page II.
Adjustment
Temperature setting, see figs. [3] and [4].
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from
the specified temperature set on the termostat handle.
• After each service on the thermostat mixer.
1. Open shut-off valve (H) and measure the temperature of the
water emerging with a thermometer, see fig. [3].
2. Turn the green regulator nut (I) clockwise - counterclockwise
with a screwdriver until the water emerging has reached a
temperature of 100 °F.
3. Fit the thermostat handle (J) so that the 100 °F mark on the
thermostat handle lines up with the mark (B) on the
sleeve (A), see fig. [4].
4. Insert fixing ring (K) and push decorative sleeve (L) on the
thermostat handle (J).
5. Push on decorative ring complete (M) or lever complete and
screw on handle cap (N).
The lever ring can be positioned in four positions. Choose
the best position suitable for the end user.
Reversed union (hot on right - cold on left).
Replace thermoelement (47 450), see replacement parts fold-
out page II, ref. No.: 47 282 (1/2").
1
English
Temperature limitation
When in proper calibration, the temperature range is limited
to 110 °F. There is a safety check at 100 °F.
If a higher temperature is desired, one can exceed 100 °F by
overriding the safety check.
Prevention of frost damage
When the domestic water system is drained, the thermostat
mixers must be drained seperately, since check valves are
installed in the hot and cold water connections.
The complete thermostat assembly and check valves must be
unscrewed and removed.
Maintenance
For Maintenance, see figs. [4], [5], [6] and fold-out page II.
I. Thermostat cartridge
1. Turn thermostat handle (47 427) or lever thermostat
handle (47 432) to the 100 °F safety check, see fold-out
page II.
2. Remove thermostat handle cap (47 428) and decorative
ring complete (47 429) or lever complete (47 433).
3. Take out fixing ring (K), see fig. [4].
4. Pull off thermostat handle (J).
5. Pull sleeve (A) from the mixer shank by pressing down
the tongue (S), see fig. [5].
6. Extract clamp (O).
7. Pull stop ring (P) until resistance is encountered
(approximately 3/8" [10mm]), see fig. [6].
8. Unscrew stop ring (P) complete with regulator nut (I).
9. Remove escutcheon (47 013).
10. Close service stop (47 017).
11. Unscrew thermostat cartridge (47 450) with 15/16"
(24mm) open-ended spanner.
Reassembly should be carried out in reverse order.
Temperature adjustment is necessary after each service of the
thermostat cartridge (see Adjustment).
II. Check valve
1. Proceed as for Maintenance of thermostat cartridge,
Points 1 - 4 and 8 - 10.
2. Unscrew check valve (14 116) with 11/16" (17mm) open-
ended spanner.
Reassembly should be carried out in reverse order.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012)
Replacement parts, see fold-out page II (* = special
accessories)
Care
Instructions for care of this fitting will be found in the Limited
Warranty supplement.